Parameter Unit Value
Model AED07KP AED09KP
Product Code CC052024200_K93412 CC052024300_K93412
Power
Supply
Rated Voltage V~ 220 220
Rated Frequency Hz 60 60
Phases 1 1
Cooling Capacity W 2110 2720
Heating Capacity W / /
Cooling Power Input W 650 840
Heating Power Input W / /
Cooling Power Current A 3 3.9
Heating Power Current A / /
Rated Input W 900 1000
Rated Current A 4.86 5.41
Air Flow Volume (H/M/L) m
3
/h 480/430/380 480/430/380
Dehumidifying Volume L/h 0.6 1
EER W/W 3.22 3.22
COP W/W / /
Application Area m
2
7-12 12-18
Climate Type T1 T1
Isolation I I
Moisture Protection IP24 IP24
Permissible Excessive Operating Pressure for
the Discharge Side
MPa 3 3
Permissible Excessive Operating Pressure for
the Suction Side
MPa 1.5 1.5
Dimension (WXHXD)
mm 560X375X668 560X375X668
Dimension of Carton Box (LXWXH) mm 763X620X410 763X620X410
Dimension of Package (LXWXH) mm 766X623X425 766X623X425
Net Weight kg 39 45
Gross Weight kg 43 49
Refrigerant R22 R22
Refrigerant Charge kg 0.5 0.7

Table of Contents

Other manuals for GE AEV07KP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE AEV07KP and is the answer not in the manual?

GE AEV07KP Specifications

General IconGeneral
BrandGE
ModelAEV07KP
CategoryAir Conditioner
LanguageEnglish

Related product manuals