Performance Data Sheet
SmartWater Filtration Sgstem-GE®MWF Cartridge
This system has been tested and certified in filter model GE HWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below, The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI Standards 42 and 53,* (Safetg factors built in for unmetered usagel
Standard No. 42: Aesthetic effects
Substance NSFSpecified Challenge Average % I Average Product I Max Permissible Product_ NSF Reduction
Reduction Average Influent Concentrat on Reduct on l Water Concentrat on Water Concentrat on URequ rements
2.0 mg/L
_ pts/mL
]
NSFTest
Report
J-00077703
J-00077704
Standard No. 53: Health effects
Substance
Reduction
10_to I(_ fibers/L; fibers
reater than 10
/L _+10%
!_+ 10%
0.08 mg/L _+10%
/L _+I0%
/L_+ 10%
/L + 10%
0.006 mg/L _+10%
/L _+10%
_L_+10%
0.015 mg/L_+ 10%
_L_+10%
0.218 mg/L 0.210 mg/L _+10%
_Basedon the use of Cryptosporidium parvum oocysts
Capacity 300gallons (1,135 liters). Contaminant reduction determined by NSF
Application GuidelineslWater Supply Parameters
Service Flow
Water Su_
NSFSpecified Challenge Average %
Concentration Reduction
Minim um 50,000 c_stsLL ......................99:99%
>99%
1
94,5%
96,7%
98.7%
95.6%
99,3%.......................................
99.3%
99% ............................................
93,2%
93,2%
99,7%
96,6%.......................................
93,2°/0
99.5%
testing,
Average Product
Water Concentration
cyst/L
<I MF/L
0.0005 m /L
0.001 mg/L
opooo2m_LL...................................................
0.0004mg/L
0.0004 m /L
0,005 m /L
Max Permissible Product
Water Concentration
NiA
NiA
0.003 m /L
0.04 mg/L
NSF Reduction
Requirements
_>99.95%
_>99%
NiA
NiA
NiA
NiA
NSFTest
Report
J-00077721
J-00077707
J-00077708
J-00077717
J-00077718
J-00082185
......................................................................................N/A .................................................................................J:999ZTZ22
N/A J-00077723
£:£££_m_£_ ...........................................................................N/A J-00077726
O.O02mg/L NiA J-00077727
0,002 m /L NiA J-00077728
0,075 m /L N_A...............................................................................................
.............................................................................................................................................................N!A J-00082184
NiA J-00077730
O.O009mg/L O,07mg/L NiA J-00077705
Water Pressure
Water Temperature
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Operating Specifications
Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33-100°F (0.6-38°C)
Flow rate: 05 gpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for i-i/2 gallons (about three minutes) to purge
trapped aiL
Replace cartridge when flow becomes too slow.
Protect from freezing by removing filter cartridge when temperatures are
expected to drop below 33°F (I°C). Do not install systems in areas where
ambient temperatures may go above IO0°F or below 40°R Do not install
on a hot water supply.
Special Notices
installation instructions are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
Do not use with water that is microbiologicallg unsafe or of unknown quality
without adequate disinfection before or after the sgstem. Systems certified for
cgst reduction may be used on disinfected water that may contain filterable cgsts.
The contaminants or other substances removed or reduced bg this water
treatment system are not necessarily in your wateL
Check for compliance with the applicable state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions,
actual performance may vary. Systems must be installed and operated in
accordance with manufacturer's recommended procedures and guidelines.
Installation and use MUSTcomplg with allstate and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552kPa),you should install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arresteL Contact a plumbing
professional if you are uncertain how to check for this condition.
Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
Tested and Certified by NSF International against ANSI/NSF Standards/42 and 53 in model GE MWF for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical
- Chlorine Taste and Odor
Mechanical Filtration
- Particulate Reduction, Class I
GE
Appliances
Appliance Park
Louisville, KY40225
gea pplia ncepa rts.com
Standard No. 53: Health Effects
Chemical Reduction
- Atrazine Reduction
- Endrin Reduction
- Benzene and Carbofuran Reduction
- 1/4 Dichlorobenzene and
2,4-D Reduction
- Leadand Lindane Reduction
- Mercury and Toxaphene Reduction
Mechanical Filtration
- Cystand AsbestosReduction
REPLACEMENT