2-166 UR FAMILY – COMMUNICATIONS GUIDE
MEMORY MAP CHAPTER 2: MODBUS COMMUNICATION
2
" C310 Spare Setting 6 0 to 1 --- 1 F102 0 (Disabled)
" C311 Spare Setting 7 0 to 1 --- 1 F102 0 (Disabled)
" C312 Spare Setting 8 0 to 1 --- 1 F102 0 (Disabled)
" C313 Spare Setting 9 0 to 65535 --- 1 F001 0
" C314 Spare Setting 10 0 to 65535 --- 1 F001 0
" C315 Spare Setting 11 0 to 65535 --- 1 F001 0
" C316 Spare Setting 12 0 to 65535 --- 1 F001 0
" C317 FLE Last Saved Timestamp 0 to 4294967295 --- 1 F050 0
" C319 FLE Last Compiled Timestamp 0 to 4294967295 --- 1 F050 0
" C31B RPN Last Saved Timestamp 0 to 4294967295 --- 1 F050 0
Mandatory (Read Only)
All C31D GFP Setting File CRC 0 to 4294967295 --- 1 F003 0
Mandatory (Read/Write Setting)
All C31F GFP USB Device Port Function 0 to 1 --- 1 F102 1 (Enabled)
" C320 GFP USB Host Port Function 0 to 1 --- 1 F102 1 (Enabled)
Clear Records (Read/Write Setting)
B30, C60, D60,
F35, F60, G60,
L60, L90, N60,
T60
C44E Clear Demand Operand 0 to 4294967295 --- 1 F300 0
C60, D30, D60,
F35, F60, L30,
L60, L90
C450 Clear Fault Reports Operand 0 to 4294967295 --- 1 F300 0
B30, B90, C70,
G30, G60, M60,
N60, T35, T60
C452 Clear User Fault Reports Operand 0 to 4294967295 --- 1 F300 0
All C454 Clear Event Records Operand 0 to 4294967295 --- 1 F300 0
All C456 Clear Oscillography Operand 0 to 4294967295 --- 1 F300 0
All except B90 C458 Clear Data Logger Operand 0 to 4294967295 --- 1 F300 0
B30, C60, C70,
D30, D60, F35,
F60, G30, G60,
L30, L60, L90,
M60, T35, T60
C45A Clear Breaker 1 Arcing Current Operand 0 to 4294967295 --- 1 F300 0
" C45C Clear Breaker 2 Arcing Current Operand 0 to 4294967295 --- 1 F300 0
B30, C60, C70,
F35, F60, L90,
T35, T60
C45E Clear Breaker 3 Arcing Current Operand 0 to 4294967295 --- 1 F300 0
B30, C60, F35,
F60, L90, T35,
T60
C460 Clear Breaker 4 Arcing Current Operand 0 to 4294967295 --- 1 F300 0
B30, F35, T35,
T60
C462 Clear Breaker 5 Arcing Current Operand 0 to 4294967295 --- 1 F300 0
" C464 Clear Breaker 6 Arcing Current Operand 0 to 4294967295 --- 1 F300 0
L30, L90 C466 Clear Channel Tests Status Operand 0 to 4294967295 --- 1 F300 0
B30, C60, D60,
F35, F60, G30,
G60, L90, M60,
N60, T60
C468 Clear Energy Operand 0 to 4294967295 --- 1 F300 0
F60 C46A Clear Hi-Z Records Operand 0 to 4294967295 --- 1 F300 0
All C46C Clear Unauthorized Access Operand 0 to 4294967295 --- 1 F300 0
M60 C46E Clear Start Data Operand 0 to 4294967295 --- 1 F300 0
Products Address Register name Range Units Step Format Default