2-186 UR FAMILY – COMMUNICATIONS GUIDE
MEMORY MAP CHAPTER 2: MODBUS COMMUNICATION
2
B30, C70, D30, D60,
F60, L30, L60, L90,
M60, N60, T60
25 Phase Directional Overcurrent 2
N60, T60 26 Phase Directional Overcurrent 3
All except B90, C30,
T35
32 Neutral Instantaneous Overcurrent 1
B30, C60, C70, D30,
D60, F35, F60, L30,
L60, L90, M60, N60,
T60
33 Neutral Instantaneous Overcurrent 2
" 34 Neutral Instantaneous Overcurrent 3
" 35 Neutral Instantaneous Overcurrent 4
" 36 Neutral Instantaneous Overcurrent 5
" 37 Neutral Instantaneous Overcurrent 6
C60, C70, D30, D60,
F35, F60, L30, L60,
L90, M60, N60, T60
38 Neutral Instantaneous Overcurrent 7
" 39 Neutral Instantaneous Overcurrent 8
" 40 Neutral Instantaneous Overcurrent 9
" 41 Neutral Instantaneous Overcurrent 10
" 42 Neutral Instantaneous Overcurrent 11
" 43 Neutral Instantaneous Overcurrent 12
B30, C60, C70, D30,
D60, F35, F60, G30,
G60, L30, L60, L90,
M60, N60, T60
48 Neutral Time Overcurrent 1
" 49 Neutral Time Overcurrent 2
B30, C60, C70, D30,
D60, F35, F60, L30,
L60, L90, M60, N60,
T60
50 Neutral Time Overcurrent 3
" 51 Neutral Time Overcurrent 4
" 52 Neutral Time Overcurrent 5
" 53 Neutral Time Overcurrent 6
C70, D30, D60, F60,
G30, G60, L30, L60,
L90, M60, T60
56 Neutral Directional Overcurrent 1
D30, D60, F60, G30,
G60, L30, L60, L90,
M60, T60
57 Neutral Directional Overcurrent 2
T60 58 Neutral Directional Overcurrent 3
C70, D30, D60, F60,
G30, G60, L60, L90,
T60
60 Negative Sequence Directional
Overcurrent 1
" 61 Negative Sequence Directional
Overcurrent 2
T60 62 Negative Sequence Directional
Overcurrent 3
B30, C60, C70, D30,
D60, F35, F60, G30,
G60, L30, L60, L90,
M60, N60, T35, T60
64 Ground Instantaneous Overcurrent 1
Products Bit
mas
k
Element
B30, C60, C70, D30,
D60, F35, F60, L30,
L60, L90, M60, N60,
T35, T60
65 Ground Instantaneous Overcurrent 2
" 66 Ground Instantaneous Overcurrent 3
" 67 Ground Instantaneous Overcurrent 4
" 68 Ground Instantaneous Overcurrent 5
" 69 Ground Instantaneous Overcurrent 6
C60, C70, D30,
D60, F35, F60, L30,
L60, L90, M60, N60,
T35, T60
70 Ground Instantaneous Overcurrent 7
" 71 Ground Instantaneous Overcurrent 8
" 72 Ground Instantaneous Overcurrent 9
" 73 Ground Instantaneous Overcurrent 10
" 74 Ground Instantaneous Overcurrent 11
" 75 Ground Instantaneous Overcurrent 12
B30, C60, C70, D30,
D60, F35, F60, G30,
G60, L30, L60, L90,
M60, N60, T35, T60
80 Ground Time Overcurrent 1
B30, C60, C70, D30,
D60, F35, F60, L30,
L60, L90, M60, N60,
T35, T60
81 Ground Time Overcurrent 2
" 82 Ground Time Overcurrent 3
" 83 Ground Time Overcurrent 4
" 84 Ground Time Overcurrent 5
" 85 Ground Time Overcurrent 6
F60, G30, G60, L90,
T35, T60
86 Restricted Ground Fault 1
" 87 Restricted Ground Fault 2
" 88 Restricted Ground Fault 3
" 89 Restricted Ground Fault 4
T35, T60 90 Restricted Ground Fault 5
" 91 Restricted Ground Fault 6
C70, D30, D60, F35,
F60, L30, L60, L90,
T60
96 Negative Sequence Instantaneous
Overcurrent 1
" 97 Negative Sequence Instantaneous
Overcurrent 2
T60 98 Negative Sequence Instantaneous
Overcurrent 3
D30, D60, G60, L90,
T60
99 Fast Distance
G30, G60 101 Change Phase Rotation
N60 102 8-bit Comparator 1
" 103 8-bit Comparator 2
" 104 8-bit Comparator 3
" 105 8-bit Comparator 4
" 106 8-bit Comparator 5
Products Bit
mas
k
Element