3-64 UR FAMILY – COMMUNICATIONS GUIDE
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS) CHAPTER 3: IEC 61850 COMMUNICATION
3
neut.instCVal Vector MX R
neut.instCVal.mag
.f
FLOAT32 IG DIFF. CURRENT magnitude, in
primary amps
R
neut.instCVal.ang
.f
FLOAT32 IG DIFF. CU UR range -180...+180 converted to 0...360R
neut.cVal Vector MX R
neut.cVal.mag.f FLOAT32 IG DIFF. CURRENT magnitude, in
primary amps, with deadband
R
neut.cVal.ang.f FLOAT32 IG DIFF. CU UR range -180...+180 converted to 0...360R
neut.units Unit CF R
neut.units.SIUnit ENUMERATED 5, the code for amps R
neut.units
.multiplier
ENUMERATED 0, the code for a multiplier of 1 R
neut.db INT32U CF LinDfPDIF1.DifAClc.neut.db R/W/C
neut.dbAng INT32U CF LinDfPDIF1.DifAClc.neut.dbAng R/W/C
neut.zeroDb INT32U CF CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
R
angRef ENUMERATED CF See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
R
RstA WYE Restraint currents R
phsθ CMV R
phsθ.instCVal Vector MX R
phsθ.instCVal.mag
.f
FLOAT32 Iθ RESTR. CURRENT magnitude,
in primary amps
R
phsθ.cVal Vector MX R
phsθ.cVal.mag.f FLOAT32 Iθ RESTR. CURRENT magnitude,
in primary amps, with deadband
R
phsθ.units Unit CF R
phsθ.units.SIUnit ENUMERATED 5, the code for amps R
phsθ.units
.multiplier
ENUMERATED 0, the code for a multiplier of 1 R
phsθ.db INT32U CF LinDfPDIF1.DifAClc.phsθ.db R/W/C
phsθ.zeroDb INT32U CF CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
R
neut CMV R
neut.instCVal Vector MX R
neut.instCVal.mag
.f
FLOAT32 IG RESTR. CURRENT magnitude,
in primary amps
R
neut.cVal Vector MX R
neut.cVal.mag.f FLOAT32 IG RESTR. CURRENT magnitude,
in primary amps, with deadband
R
neut.units Unit CF R
neut.units.SIUnit ENUMERATED 5, the code for amps R
neut.units
.multiplier
ENUMERATED 0, the code for a multiplier of 1 R
neut.db INT32U CF LinDfPDIF1.DifAClc.neut.db R/W/C
neut.zeroDb INT32U CF CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
R
angRef ENUMERATED CF See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
R
InRef001 ORG CHNL ASYM COMP setting. R
setSrcRef ObjectReference SP CHNL ASYM COMP setting reference to the data attribute to input R/C
setSrcCB ObjectReference SP source GoCB of input if via GOOSE R/C
BlkRef9 ORG BLOCK GPS TIME REF setting. R
setSrcRef ObjectReference SP BLOCK GPS TIME REF setting reference to the data attribute to input R/C
setSrcCB ObjectReference SP source GoCB of input if via GOOSE R/C
BlkRefγ ORG CURRENT DIFF BLOCK setting of setting
group γ.
R
LNName: LinDfPDIF1 LDevice inst: Prot UR element: Line Differential element (ANSI 87L) phase and general
functions
data obj. data attribute Type FC UR Name Description R/W/C