3-122 UR FAMILY – COMMUNICATIONS GUIDE
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS) CHAPTER 3: IEC 61850 COMMUNICATION
3
3.5.3.9 Capacitor control (CapCtl)
This element is instantiated in the following products: C70.
Table 3-145: Capacitor control data objects
units.multiplier ENUMERATED 0 R
db INT32U CF BknRotSVBR1.MaxLoadDev.db R/W/C
zeroDb INT32U CF 0 R
TmOfMax INS TIME OF MAXIMUM BRB actual value R
stVal INT32 ST TIME OF MAXIMUM BRB actual
value
R
units Unit CF R
units.SIUnit ENUMERATED 4 R
units.multiplier ENUMERATED 0 R
BknRotClr SPC Mapped to command CLEAR BROKEN
ROTOR BAR DATA
R/Ctrl
pulseConfig PulseConfig CF R
pulseConfig
.cmdQual
ENUMERATED 0 (pulse) R
pulseConfig.onDur INT32U 0 R
pulseConfig
.offDur
INT32U 0 R
pulseConfig
.numPls
INT32U 1 R
ctlModel CtlModels CF BknRotSVBR1.BknRotClr.ctlModel R/W/C
sboTimeout INT32U CF 30000 R
sboClass SboClasses CF 0 (operate-once) R
operTimeout INT32U CF 0 R
LNName: CapCtlGAPC# LDevice inst: Ctrl UR element: Capacitor control element #
data obj. data attribute Type FC UR Name Description R/W/C
RemMod SPS CAP # IN REMOTE operand R
stVal BOOLEAN ST CAP # IN REMOTE R
LocMod SPS CAP # IN LOCAL operand R
stVal BOOLEAN ST CAP # IN LOCAL R
AutoMod SPS ”CAP # IN AUTO operand R
stVal BOOLEAN ST CAP # IN AUTO R
ManMod SPS ”CAP # IN MAN operand R
stVal BOOLEAN ST CAP # IN MAN R
Dischargin
g
SPS ”CAP # DISCHARGING operand R
stVal BOOLEAN ST CAP # DISCHARGING R
OpOpn ACT CAP # BKR TRIP operand R
general BOOLEAN ST CAP # BKR TRIP R
OpCls ACT CAP # BKR CLOSE operand R
general BOOLEAN ST CAP # BKR CLOSE R
DischargeT
ms
MV CAP # DISCHARGE TIME in seconds R
instMag AnalogueValue MX R
instMag.f FLOAT32 CAP # DISCHARGE TIME actual
value
R
mag AnalogueValue MX R
mag.f FLOAT32 instMag.f deadbanded R
units Unit CF R
units.SIUnit ENUMERATED 4, the code for time (s) R
units.multiplier ENUMERATED 0, the code for a multiplier of 1 R
LNName: BknRotSVBR1 LDevice inst: Ctrl UR element: Broken Rotor Bar element
data obj. data attribute Type FC UR Name Description R/W/C