Test 12 Drain Pump Test Press the Start key to begin the test.
Drain pump comes on and P1 is displayed in the display.
Test 13 Heater Test •  Press the Start key to begin the test.
•  Water temperature in °F is displayed in the display.
•  If water is present at the start of the test, the tub will be drained to 
empty. Otherwise, the tub will fi ll to the appropriate water level and the 
heater will be turned on.
Note: If at any time during the test the water level gets too low, the heater 
will be turned off  and the water valve will be turned on until the water 
level reaches a safe heater operating temperature, then the heater will be 
turned back on.
Test 14 Door Lock Test •  Press the Start key to begin the test.
•  The door will lock and LC will be displayed in the display.
• Pressing the Start key again will unlock the door and UL will be 
displayed in the display.
Test 15 Out of Balance 
Test
• Press the Start key to begin the test.
•  If water is present at the start of the test, the tub will be drained to 
empty. 
•  Washer spins at 100 RPM and OOB value will be displayed in the 
displayed will display.
Test 16 Pressure Sensor 
Test
• Press the Start key to begin the test.
•  If water is present at the start of the test, the tub will be drained to 
empty. 
•  Hot and cold water valves are energized and the pressure sensor 
frequency is displayed in the display with 1 decimal point of resolution. 
(i.e.: XX.X Hz. See Pressure Sensor for frequencies.) 
Note: The control will continue fi lling until the overfl ow level is reached, 
at that time the water valves will be turned off  and the drain pump will be 
energized until the tub is drained to empty.
Test 17 Flow Meter Test •  Press the Start key to begin the test.
•  If water is present at the start of the test, the tub will be drained to 
empty. 
•  Hot and cold water valves are energized and the fl ow rate in liters/
minute is displayed in the display with 1 decimal point of resolution. 
(i.e.: XX.X L/M)
Note: The control will continue fi lling until the overfl ow level is reached, 
at that time the water valves will be turned off  and the drain pump will be 
energized until the tub is drained to empty.
Test 18 UI Critical 
Software Version 
Check
• Press the Start key to begin the test.
•  Major software version of the UI software is displayed in the display 
for 1 second and the Extra Heavy LED is on.
•  Minor software version of the UI software is displayed in the display 
for 1 second and the 
Heavy LED is on.
The display will continue to toggle between the 2 versions until the user 
exits the test.