About the water softener sgstem.
Service: Manually Initiuted Electronics Diognostics
1. To enter diagnostics, press and hold
the MODE button for 3 seconds until
the Low Salt Alarm screen shows.
2. Pressthe MODE button 2 times
to advance through Low Salt Alarm
and Salt Efficiency options. See
Programming the Contro! for
details on these two options.
m
4;)) IJ I-!
s#'[ I:I I:ILI I_! !_!l-i i-I I-t
3. OPERATION OF DIAGNOSTICS
Motor Position
Valve _ _,/switch
position c'"I-U
u
f
Water meter
Valve Position - Pressthe RECHARGE_ button to initiate
a recharge cycle. Press again to manually index valve to
next position. See Service: Monuo!ly Advance Recharge
Checkfor details.
0 - Service
1 - Fill
2 - Brine
] - Backwash
4 - Fast Rinse
Motor Operation - Two dashes will circulate around
when motor should be running.
Position Switch Operation -
r
L - Closed - valve rotating to next position
n
u - Open - valve in position, service, fill, brine, etc.
Water Meter - Indicates whether water is flowing
through valve.
Position
switch
i
, housing
J
Valve
outlet
support
and shaft
- 000 indicates no water is flowing through the valve
- Open nearby soft water faucet
- 000 to 14! (continual) shows water is flowing. Display
repeats for each gallon of water passing through the
meter. Control will beep at every gallon.
- If there is no reading in the display, with faucet open,
check the sensor. Pull the sensor from the valve outlet
port, and pass a small magnet in front of the sensor.
Counter should index in the display. If counter does
not index, check to make sure harness isconnected
to board properly. If there is a reading in the display,
there man be a problem associated with the turbine.
Turn off water supply, close the bypass valve and
disconnect bypass valve from body. Check turbine
for binding or restriction due to debris. If this does
not correct the problem, the Timer, Sensor or Turbine
man require replacement.
4. Historical data about the softener is available.
Press and hold the UP button to display the number
of days this control has had electrical power applied.
Press and hold the DOWN button to display the
number of recharges initiated by this control since the
model code number was entered.
5. Pressthe MODE button to return to normal operation
and display.
Service: Set Model (F or HI Code
1. To change or check model code, first press and hold the
MODE button for ] seconds until the Low Salt Alarm screen
shows.
2. Pressand hold the MODE button again %El
for ] seconds. A display with L od at
the top will appear.
3. Pressthe UP or DOWN buttons to
select the correct model code.
r,]
LOo
-io i /
H:,:, !_]
F]I-GXSF]IE, F]5-GXSF]5E, F40-GXSF40H
H]g-GXSH]gE, H45-GNSH45E
4. Pressthe MODE button one time to return to normal
operation and display. If the model code was changed:
the display will go blank momentarily, then display the
model code entered.
the display will then return to the set present time display,
and the blue indicator light will flash. The control will have
to be reprogrammed. See Programming the Contro!.
NOTE:If the control is left in ann of the above diagnostic
displays, or a flashing display when setting time, hardness,
etc., it will revert back to the normal display in 4 minutes.