BASIC OPERATION AND FEATURES
SX TRANSISTOR CONTROL Page 9
July 1999
Section 2.3.4.a Internal Resistance Compensation
This feature is used when the Battery Discharge Indicator
is present. Adjustment of this function optimizes BDI with
among different brands of batteries.
Section 2.3.5 Handset
This is a multi-functional tool used with the LX, ZX, and SX
Series GE solid state controls. The Handset consists of a
Light Emitting Diode (LED) display and a keyboard for data
entry. Note, for ordering purposes, a separate handset part
number is required for SX controls.
Features and functions:
= Monitor existing system status codes for both traction
and pump controls. Monitor intermittent random status
codes.
= Monitor battery state of charge, if available.
= Monitor hourmeter reading on traction and pump
controls.
= Monitor or adjust the control functions.
Section 2.3.6 RS232 Communication Port
The serial communication port is used for communication
between the two controllers for the transmission of fault
codes, confirmation of setup parameters and start-up
diagnostics. It can also be used to change control set-up
parameters.
Section 2.3.7 Circuit Board Coil Driver Modules
Coil drivers are internal to the control card, and are the
power devices that operate the Line, 1A and SP contactor
coils. On command from the control card, these drivers
initiate opening and closing the contactor coils. All driver
modules are equipped with reverse battery protection, such
that, if the battery is connected incorrectly, the contactors
can not be closed electrically.
Section 2.3.8 Selectable Truck Modes
Through the adjustment of Function 1 of the controller, the
following truck parameters are automatically adjusted to
the values set below:
Description Mode 1 Mode 2 Mode 3
Function 1
Setting
0 - 63 64 - 127 128 - 255
C/A Rate
Function 48
of Handset
Function 97
of Computer
Function 53
of Handset
Function 102
of Computer
Function 58
of Handset
Function 107
of Computer
FW Start
Function 49
of Handset
Function 54
of Handset
Function 59
of Handset
Function 98
of Computer
Function 103
of Computer
Function 108
of Computer
Minimum
Field
Function 50
of Handset
Function 99
of Computer
Function 55
of Handset
Function 104
of Computer
Function 60
of Handset
Function 109
of Computer
Ratio
Function 51
of Handset
Function 100
of Computer
Function 56
of Handset
Function 101
of Computer
Function 61
of Handset
Function 110
of Computer
Regen
Current
Limit
Function 52
of Handset
Function 101
of Computer
Function 57
of Handset
Function 106
of Computer
Function 62
of Handset
Function 111
of Computer

Table of Contents