EasyManua.ls Logo

GE IC3645SR4U454Z2 - Page 36

GE IC3645SR4U454Z2
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 36
January 1999
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-46
“Look Ahead” test for A2 volts less
than 12% of battery volts.
This status code will be displayed when the voltage at
A2 is less than 12% of battery volts.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Line contactor will not pick up.
POSSIBLE CAUSE
Check for short circuit from the motor armature
to the frame of the vehicle.
Defective control.
= Replace controller unit.
POWER CONNECTIONS
LEFT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
FU4
A1
A2
S1
S2
SP
+
-
FU1
POWER CONNECTIONS
RIGHT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
L
P1 P17 P2 P6 P3 P4 P5
SEAT SW.
START SW.
FORWARD SW.
REVERSE
SW.
P23 P22P10 P13
SERIAL RECEIVE
SERIAL TRANSMIT
BDI INTERRUPT
P14 P15
I-MOTOR OUTPUT
BRAKESW.
STEER PUMP
FIELD
STEER PUMP
ARM
P11 P18
1A OR SP DVR
PLUG/RGN
OUTPUT
LEFT
CONTROL
(MASTER)
TO PUMP
CONTROL
POSITIVE
TO PUMP CONTROL POSITIVE
LINE
SPEED LIMIT SWITCH
FU3
KEY SWITCH
BRAKE SW.
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-49
Motor field current is too low during the
run mode.
This status code will be displayed when the current
draw in the motor field is too low during the run mode.
MEMORY RECALL
NO
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Defective control.
= Replace controller unit.
NO GRAPHIC FOR THIS
STATUS CODE

Table of Contents

Related product manuals