DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 41
January 1999
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-80
Voltage at capacitor (1C) is less than
14 volts.
This status code will be displayed when the voltage at
the capacitor is less than 14 volts. This typically
occurs during the run mode of operation.
MEMORY RECALL
YES
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Line contactor opened during run.
•= Check connection from P17 to Line Coil (-) for
loose connection.
•= Check connection from battery (+) to Line Coil
(+) for loose connection.
•= Check power connection from battery (+) to
contactor L.
•= Check for blown fuse element.
•= Check for contaminated contactor tips.
POWER CONNECTIONS
LEFT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
FU4
A1
A2
S1
S2
SP
+
-
FU1
POWER CONNECTIONS
RIGHT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
L
P1 P17 P2 P6 P3 P4 P5
SEAT SW.
START SW.
FORWARD SW.
REVERSE
SW.
P23 P22P10 P13
SERIAL RECEIVE
SERIAL TRANSMIT
BDI INTERRUPT
P14 P15
I-MOTOR OUTPUT
BRAKESW.
STEER PUMP
FIELD
STEER PUMP
ARM
P11 P18
1A OR SP DVR
PLUG/RGN
OUTPUT
LEFT
CONTROL
(MASTER)
TO PUMP
CONTROL
POSITIVE
TO PUMP CONTROL POSITIVE
LINE
SPEED LIMIT SWITCH
FU3
KEY SWITCH
BRAKE SW.
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-81
Battery voltage is less than 14 volts. This status code will be displayed when the battery
voltage measured at P1 is less than 14 volts.
MEMORY RECALL
YES
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
Line contactor opened during run.
•= Check connection from P17 to Line Coil (-) for
loose connection.
•= Check connection from battery (+) to Line Coil
(+) for loose connection.
•= Check power connection from battery (+) to
contactor L.
•= Check for blown fuse element.
POWER CONNECTIONS
LEFT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
FU4
A1
A2
S1
S2
SP
+
-
FU1
POWER CONNECTIONS
RIGHT CONTROL
POS A1 F1
NEG A2 F2
FIELD
ARMATURE
L
P1 P17 P2 P6 P3 P4 P5
SEAT SW.
START SW.
FORWARD SW.
REVERSE
SW.
P23 P22P10 P13
SERIAL RECEIVE
SERIAL TRANSMIT
BDI INTERRUPT
P14 P15
I-MOTOR OUTPUT
BRAKESW.
STEER PUMP
FIELD
STEER PUMP
ARM
P11 P18
1A OR SP DVR
PLUG/RGN
OUTPUT
LEFT
CONTROL
(MASTER)
TO PUMP
CONTROL
POSITIVE
TO PUMP CONTROL POSITIVE
LINE
SPEED LIMIT SWITCH
FU3
KEY SWITCH
BRAKE SW.