ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS Page 64
January 1999
code pointer number" [the number shown in (bold italics)
in the HS (Handset) number column] on the memory map,
with the number obtained from Function 28. This will be the
last stored status code recorded.
Note: When scrolling through the stored status code
register, the register always starts at status code 1 and
scrolls to status code 16. Instructions for scrolling the
register are in section 7.3.2 of this instruction booklet.
FUNCTION 48 MODE 1 (TURTLE) - ARMATURE
CONTROLLED ACCELERATION AND 1A
TIME
(Push CONT 1)
This function allows for the adjustment of the rate of time it
takes for the control to accelerate to 100% applied battery
voltage to the motor on hard acceleration. The 1A contactor
will automatically close 0.2 seconds after the controlled
acceleration stops and the accelerator input is less than 0.5
volts or less than 200 ohms.
Range 0.1 to 22.0 seconds
Set 0 to 255
Resolution 0.084 seconds per set unit
Example Setting of 20 = 1.78 seconds C/A
and 1.98 seconds 1A time
This C/A AND 1A TIME takes effect when the Mode 1
settings are called for by the Interactive Dash Display.
FUNCTION 49 MODE 1 REGEN CURRENT LIMIT
(Push CONT 2)
Same as Function 9.
FUNCTION 50 MODE 1 BRAKE PEDAL REGEN
(Push CONT 3)
Same as Function 21.
FUNCTION 51 MODE 1 SPEED LIMIT 2
(Push CONT 4)
Same as Function 12.
FUNCTION 52 MODE 2 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 5)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 2
settings are called for by the Interactive Dash Display.
FUNCTION 53 MODE 2 REGEN CURRENT LIMIT
(Push CONT 6)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 2 settings are called for by the Interactive Dash
Display.
FUNCTION 54 MODE 2 BRAKE PEDAL REGEN
(Push CONT 7)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 2 settings are called for by the Interactive Dash
Display.
FUNCTION 55 MODE 2 SPEED LIMIT 2
(Push CONT 8)
Same as Function 51.
This RATIO takes effect when the Mode 2 settings are
called for by the Interactive Dash Display.
FUNCTION 56 MODE 3 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 9)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 3
settings are called for by the Interactive Dash Display.
DASH DISPLAY INTERACTIVE MODES
The following functions (Functions 48 through 62) are
mode settings that are activated from the Interactive
Dash Display. Each function must be set using the logic
table shown below. If you try to set this function outside
these guidelines, an error code will be displayed to
prompt you to enter the correct setting:
If “80” is displayed, the setting is too low.
If “81” is displayed, the setting is too high.
Note: The following functions have function numbers
larger than the numbers on the Handset keyboard. To
access these functions, push the CONT key and the
number shown in the following instructions at the same
time. The seat switch must be closed.