Installation Instructions
Electrical Connections
ATTENTION INSTALLER
All electric wall ovens must be hard wired
(direct wired) into an approved junction box. A
plug and receptacle is NOT permitted on these
products.
DO NOTVKRUWHQWKHÀH[LEOHFRQGXLW
The conduit strain relief clamp must be securely
DWWDFKHGWRWKHMXQFWLRQER[DQGWKHÀH[LEOH
conduit must be securely attached to the
FODPS,IWKHÀH[LEOHFRQGXLWZLOOQRW¿WZLWKLQ
the clamp, do not install the oven until a clamp
of the proper size is obtained.
NOTE TO ELECTRICIAN: The 3 power leads
supplied with this appliance are CSA
recognized for connection to heavier gauge
household wiring. The insulation of these 3
leads is rated at temperatures much higher
than the temperature rating of household
wiring. The current carrying capacity of the
conductor is governed by the wire gauge
and the temperature rating of the insulation
around the wire.
7XUQRIIWKHFLUFXLWEUHDNHURUUHPRYHIXVHV
WRWKHRYHQEUDQFKFLUFXLW
:LWKWKHRYHQVXSSRUWHGRQDWDEOHRU
SODWIRUPLQIURQWRIWKHFDELQHWRSHQLQJ
FRQQHFWWKHÀH[LEOHFRQGXLWWRWKHHOHFWULFDO
MXQFWLRQER[DVVKRZQEHORZ3RVLWLRQWKH
FRQGXLWLQVXFKDPDQQHUWKDWLWZLOOIDOORQ
WKHULJKWEDFNVLGHRIWKHRYHQLQDQDWXUDO
ORRSZKHQWKHRYHQLVLQVWDOOHG<RXZLOO
QHHGWRSXUFKDVHDQDSSURSULDWHVWUDLQ
UHOLHIFODPSWRFRPSOHWHWKHFRQQHFWLRQRI
WKHFRQGXLWWRWKHMXQFWLRQER[
WARNING: Improper
connection of aluminum house
wiring to copper leads can result
LQDQHOHFWULFDOKD]DUGRU¿UH8VHRQO\
connectors designed for joining copper to
aluminum and follow the manufacturer’s
recommended procedure closely.
B2
B3
B4
B1
7KLVRYHQLVVXSSOLHGZLWKDFPµ
ORQJÀH[LEOHFRQGXLWFRQVLVWLQJRI
3 insulated conductors (copper)
1 bare ground conductor (copper)
$WWDFKFRQGXFWRUVWRUHVLGHQFHZLULQJDV
VKRZQE\ZLULQJGLDJUDP
Strain Relief Clamp
(not included) must be
used at Junction Box
B
Junction Box
Location
BARE
GROUND
WHITE
Place oven on a
support to assist in
connecting conduit
RED
%/$&.
Conduit
GROUND
WIRE

Other manuals for GE JCK5000