18 49-2000738 Rev. 0
Instrucciones de Instalación
LISTAS DE VERIFICACIÓN
1
LISTA DE VERIFICACIÓN PREVIA
A
Retire toda la película protectora, si la hay, y las
calcomanías.
B
&KHFNWREHVXUHWKDWDOOZLULQJLVVHFXUHDQGQRW
SLQFKHGRULQFRQWDFWZLWKPRYLQJSDUWV
C
&KHFNOHYHORIDSSOLDQFH
D
&KHFNWKDWWKHFRRNWRSLVSURSHUO\JURXQGHG
2
OPERATION CHECKLIST
A
5HPRYHDOOLWHPVIURPWKHWRSRIWKHFRRNWRS
surface.
B
7XUQRQWKHSRZHUWRWKHFRRNWRS9HULI\WKDWDOO
surface burners operate properly.
C
&KHFNWKDWWKHFLUFXLWEUHDNHULVQRWWULSSHGQRU
WKHKRXVHIXVHEORZQ
D
&KHFNWKDWFRQGXLWLVVHFXUHO\FRQQHFWHGWRWKH
junction box.
E
See troubleshooting list.
NOTE TO ELECTRICIAN:
The power leads supplied with this appliance
are UL recognized for connections to larger
gauge household wiring. The insulation of these
leads is rated at temperatures much higher than
the temperature rating of household wiring.
The current carrying capacity of a conductor
is governed by the wire gauge and also the
temperature rating of the insulation around the
wire.
NOTE: ALUMINUM WIRING
WARNING
IMPROPER CONNECTION OF ALUMINUM
HOUSE WIRING TO THE COPPER LEADS
CAN RESULT IN A SERIOUS PROBLEM.
Splice copper wires to aluminum wiring
using special connectors designed and UL
approved for joining copper to aluminum
and follow the manufacturer’s recommended
connector procedure closely.
NOTE: Wire used, location and enclosure of
splices, etc., must conform to good wiring
practice and local codes.
INSTRUCCIONES DE INSTALACIÓN