EasyManua.ls Logo

GE Masoneilan 4700E - Mounting 4700 P and 4700 E on Series 87;88 Actuators

GE Masoneilan 4700E
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2015 General Electric Company. All rights reserved.
24 | =GE Oil & Gas
Mounting 4700P and 4700E on Series 87/88 Actuators
1. Using screws (113) and lockwashers (114), mount bracket (115) on actuator with
opening located to the right side of the bracket (Figure 5).
2. Install input shaft (42) in post hub with a washer (40) on each side of the hub and
r
etaining ring (37) on cam end.
3. Mount back lever (103) to input shaft using screw (38) and lockwasher (39).
4. Install clevis (102), clevis pin (104), washer (122),
and retaining clip (105) in the
proper location on the back lever. Location is based on valve stroke required.
5. Check Figure 6 for proper mounting location for positioner on bracket.
6. Mount positioner on bracket using socket head screws (29) and lockwashers (30).
NOTE Back lever must be behind bracket.
7. Mount cam (26) on input shaft using washer (27) and screw (28) with desired lobe
ag
ainst cam follower. (Do not mount cam if positioner is reverse action).
8. Connect turnbuckle (106), locknut (107), turnbuckle screw (101), locknut (108), and
clamp r
od (100).
Model Travel (mm) Travel (in.) Hole Location
4700 20.3 .8 A
4700 25.4 1.0 B
4700/4800 38.1 1.5 C
4700/4800 50.8 2.0 D
4700/4800 63.5 2.5 E
NOTE Strokes shorter than 20.3 mm (0.8"), require a special mounting