¾ The 3-way valve is used to direct refrigerant flow.
¾ The valve has four different positions.
They are referred to by the letters ‘A, ‘B’, ‘C’ and ‘D’
A = Open to the Fresh Food and Freezer evaporators in series (refrigerant
flows through the fresh food evaporator and then into the freezer
evaporator). This is also called the (Home Position)
B = Open to the Freezer evaporator only
C = Open to both the Fresh Food and Freezer evaporators via the individual
capillary tubes (this position is not currently used on these models)
D = Closed to both Fresh Food and Freezer evaporators during the off cycle
3-Way Valve