Installationof the warming drawer.
Read these instructions completely and carefully.
RemovePackagingand Parts
Parts provided: 4"Wood screws
[] Place carton on a fiat surfi_ce.
[] Open one end of the carton and lift off
the top piece.
[] I,ifl the wamfing drawer up and out of
[he ca I'[on,
[] Place the drawer on top of the shipping
carton to protect the drawer fl'ont and the
finished flooring.
[] Remoxe all packing materials and tape.
[] I,ocate package containing 4 wood screws
and set aside.
/nsta//ation Be/ow a Countertop
Electricaloutlet42" max.
rearcabinetwall 9"
fromfloorto bottom
ofblock
fromleftside
25'L__1V/' Cabinettop
36*'
Countertop
height
, WARNING!
IN CANADATHISDRAWERIS NOT
APPROVEDFORINSTALLATION
UNDERA COOKTOP
231//' Min.
Installasolidbarrier
anda 1/4" rain.air gap
abovewarmingdrawer
DimensionA
27" Drawer 30" Drawer
25W" 28W"
*NOTE.,When installing the warming drawer below a cooktop,
a sofidbarrier mustbe &stalled at least I" from the lowest point
of the bottom of coold:opbemer box to the top ofcutout. Use any
solid material such as I/4" thickplywood. Allow at least I/4" air
gap between the barrier and the top of the warmflTgdrawe_See
label on top ofthe warmflTgdrawer for approved co&top models.
_,_q_en installed, the fl'ont fi_ce of the wamfing
drawer will be nearly flush with cabinet_ do(n_ or
(h'awer tl"oIlts,
Drawer overlaps will conceal cut edges on all sides
of the opening.
The roughopening forthe drawer must be:
--Depth: 23½" minimum fl'om inside back to fi'ont
of cabinet fl'am e.
' _[ " " 27"--Width: 2a½ for xdcle models
28 ½" for 30" wide models.
--Height: 9¼"
5" minim um above floor or 1" above toekick. 23¼"
ti'OIl/ _10oI" to bottoI// of CtltOtlt is i'ecoi//illended
for under countertop installation.
12
Installation below a cabinet drawer:
The wamfing drawer may be installed beneath a cabinet
(h'awe_: In this installation, a solid barrier should be
installed above the wamfing drawer to block access.
Use any solid material such as l/4" thick plywood. Mlow
at least l/4" air gap between the barrier and the top of
the wamfing drawer Observe the 5" rain. above the floor
or 1" above the toekick rain. installation height.
/VOTE'.If you are installing in fl'ameless cabinets, it may
be necessmw to install 1/9" wide cleats to accept drawer
motmting screws. See drawer to find exact locations of
illOtlnting sci'e_:s.
When installed under a cooktop:
_.Vamfing (h'awe_ are suitable fin" installation below only
certain specified cooktop models. See the label attached
to the top of the wamfing drawer fin" suitable models. A
solid barrier and air gap between cooktop and wamfing
drawer is required. See Note above.