GE Power Break II Specifications

General IconGeneral
Voltage Rating600V AC (various models)
Interrupting Capacity42kA - 200kA (various models)
Poles2, 3
Standards ComplianceUL
Mounting TypeFixed, Drawout
Trip Unit TypeElectronic

Summary

Power Break II Circuit Breakers

Advanced Solid-State Trip Units

Introduces MicroVersaTrip Plus/PM and Power+ trip units for breaker control.

Features and Characteristics

Power+ Trip Units

Power+ Trip Unit System Components

Outlines the trip unit, actuator, sensors, and rating plugs forming the system.

Protective Function Settings

Lists standard and optional protective functions available with Power+ trip units.

MicroVersaTrip Plus and PM Trip Units

MicroVersaTrip System Overview

Describes the trip unit system, its components, and functions for Power Break II.

Protective Function Options

Details standard and optional protective functions for MicroVersaTrip Plus/PM.

Accessories

Catalog Numbers

Power+ Trip Unit Catalog Numbers

Details the catalog number structure for Power+ trip units.

MicroVersaTrip Plus and PM Trip Unit Catalog Numbers

Describes the catalog number system for MicroVersaTrip Plus/PM trip units.

Application

Standards and Testing Compliance

Lists UL, NEMA, IEC, ANSI, and ASTM standards and testing procedures.

Short-Circuit Breaking Capacity

Explains Ics, Icu, and Icw ratings and related verification tests.

Interrupting Ratings and Derating

Explains interrupting ratings, power factor, X/R ratios, and derating factors.

Time Current Tripping Characteristics

Describes the information presented in time-current curves for breaker performance.

Physical Data

Standards and References

Guide Form Specifications

General Requirements for Circuit Breakers

Specifies construction, ratings, UL listing, and operational features required.

MicroVersaTrip Protective System Requirements

Details features, functions, and protective capabilities for MicroVersaTrip trip units.

Power+ Protective System Requirements

Outlines features, functions, and protective capabilities for Power+ trip units.