INSTALLATION PREPARATION
Installation Preparation
INSTALLATION HEIGHT TABLE
(UX12DC93SS or
UX12DC93TS)
(UX14DC93SS or
UX14DC93TS)
Installation Height with Supplied Duct Covers
Optional High Ceiling Duct Cover
up to 12 ft.
(not included with unit)
Optional High Ceiling Duct Cover
up to 14 ft.
(not included with unit)
Ceiling
Height (ft./in.)
Possible Vented
Install Height
(in.)
Possible Vented
Install Height
(Recirculation
vented Holes
Hidden) (in.)
Possible
Recirculation
Install
Height (in.)
Ceiling
Height (ft./in.)
Vented and
Recirculation
Height (in.)
Ceiling
Height (in.)
Vented and
Recirculation
Install
Height (in.)
7' 6" 24 24 9' 3" 24 12' 24-36
7' 7" 24-25 24-25 9' 4" 24-25 12' 1" 24-36
7' 8" 24-26 24-26 9' 5" 24-26 12' 2" 24-36
7' 9" 24-27 24-27 9' 6" 24-27 12' 3" 24-36
7' 10" 24-28 24-28 24 9' 7" 24-28 12' 4" 24-36
7' 11" 24-29 24-29 24-25 9' 8" 24-29 12' 5" 24-36
8' 24-30 24-30 24-26 9' 9" 24-30 12' 6" 24-36
8' 1" 24-31 24-31 24-27 9' 10" 24-31 12' 7" 24-36
8' 2" 24-32 24-32 24-28 9' 11" 24-32 12' 8" 24-36
8' 3" 24-33 24-33 24-29 10' 24-33 12' 9" 24-36
8' 4" 24-34 24-34 24-30 10' 1" 24-34 12' 10" 24-36
8' 5" 24-35 24-35 24-31 10' 2" 24-35 12' 11" 24-36
8' 6" 24-36 24-36 24-32 10' 3" 24-36 13' 24-36
8' 7" 24-36 24-36 24-33 10' 4" 24-36 13' 1" 25-36
8' 8" 24-36 24-36 24-34 10'5"-11'3" 24-36 13' 2" 26-36
8' 9" 24-36 24-36 24-35 11' 4" 24-36 13' 3" 27-36
8' 10" 24-36 24-36 24-36 11'5" 24-36 13' 4" 28-36
8' 11" 24-36 24-36 24-36 11'6" 24-36 13' 5" 29-36
9' 24-36 24-36 24-36 11'7" 24-36 13' 6" 30-36
9' 1" 24-36 24-36 24-36 11'8" 25-36 13' 7" 31-36
9' 2" 24-36 25-36 24-36 11'9" 26-36 13' 8" 32-36
9' 3" 24-36 26-36 24-36 11'10" 27-36 13' 9" 33-36
9' 4" 24-36 27-36 24-36 11' 11" 28-36 13' 10" 34-36
9' 5" 24-36 28-36 24-36 12' 29-36 13' 11" 35-36
9' 6" 25-36 29-36 25-36 14' 36
9' 7" 26-36 30-36 26-36
9' 8" 27-36 31-36 27-36
9' 9" 28-36 32-36 28-36
9' 10" 29-36 33-36 29-36
9' 11" 30-36 34-36 30-36
10' 31-36 35-36 31-36
10' 1" 32-36 36 32-36
10' 2" 33-36 33-36
10' 3" 34-36 34-36
10' 4" 35-36 35-36
10' 5" 36 36
*Based on a 36" electric range height.
For gas range, start chart at 92" and subtract 2" for the maximum install height for each block.
7/8Ǝ min
29-7/16Ǝ max
7/8Ǝ min
46-1/4Ǝ max
46-7/8" 46-7/8"
12" High Ceiling Duct Cover Kit 14" High Ceiling Duct Cover Kit
Upper
Duct Cover
Upper
Duct Cover
Lower
Duct Cover
Lower
Duct Cover
Hood Body Hood Body