– 33 –
Drain pump will be activated when main PC board
detects frequency under 22KHz. (Flood Protection) In
ood protection mode, pump will run until reset level
is reached. Flood protection is active even in the idle
mode, as long as door is closed.
Operation of the water level sensor can be checked
by using service test mode t05. (See Service Mode.)
Speci c failures associated with the water level
sensor can initiate error codes OE and 1E. (See Error
Codes.)
The wash water level is approximately 1 ¼ inches
deep at the bottom center of the wash basket.
The over ow water level is approximately 10 inches
above the bottom of the door opening. Over ow
protection will occur at this water level.
The reset water level is approximately 3/16 inches
deep at the bottom center of the wash basket.