Malfunction Cause Rectification
<Ready for welding>
LED display
flashes, and
<Malfunction>
lights up.
Too many serial
welding joints.
Reduce the number of
welding joints (see i ,
page393)
<Malfunction> LED
display
flashes.
Electrofusion
tool is defective.
Send the electrofusion
tool to an authorised
repair shop
1)
.
<Mains connection>,
<Ready for welding>
and
<Welding complete>
LED displays
light up, and
<Malfunction> LED
display
flashes.
Worn coupling
connection
plugs or too
many inter-
ruptions from
removing the
coupling
connection
plugs during
welding
procedure.
Disconnect the mains
plug.
Visually inspect the
coupling connection
plugs and coupling
connection cables if
necessary, or replace
the connecting cables.
Send the electrofusion
tool to an authorised
repair shop
1)
.
1) The addresses of authorised repair shops can be requested from Geberit
sales companies.