1514
in.k450 in.k450
Filter cycle frequency
Press Prog. key a fourth time.
The display will show FFxx, with
"xx" representing the number of
filter cycles per day (up to 4).
Use Up or Down key to
change setting.
Setting temperature unit
Water temperature can be
displayed in either Fahrenheit
(˚F) or Celsius (˚C). Press Prog.
key a fifth time. The display will
show either ˚F or ˚C.
Use Up or Down key to
change setting.
Press Prog. key once more to go
back to normal mode.
Note: "F" will be displayed in
in.ye Spa Packs.
Smart Winter Mode
Our Smart Winter Mode
protects your system from
the cold by turning pumps on
several times a day to prevent
water from freezing in pipes.
When temperatures around
pack drop to near freezing, the
system will enter Smart Winter
Mode. The pack will cycle
through all pumps on high for
1 minute to prevent water from
freezing in the lines.
Water temperature regulation
In a regulation cycle, the system
first generates water flow
through the heater housing
and the plumbing, in order
to ensure accurate water
temperature readings as well as
avoiding heater activation in dry
conditions.
After verifying pump activation
and taking a water temperature
reading if required, the system
automatically turns the heater
on to reach and maintain water
temperature at Set Point.
Cooldown
After heating the spa water to
the desired Set Point, the
heater is turned off, but its
associated pump (Pump 1
Low-speed or CP) remains on
for a predetermined period of
time to ensure adequate
cooling of the heating element,
this prolongs its useful life.
The heater icon flashes during
this time.
functions and user instructionsfunctions and user instructions
Setting the time
Enter Programming mode by
holding Prog. key pressed down
for 3 sec. The display will show
the current time setting.
Setting the hour: Use Up or
Down arrows to change hour
setting (AM/PM).
Setting the minutes: Press Prog.
key a second time.
Use Up or Down key to change
hour setting.
Setting filter cycle start time
To program the filter cycle, you
must enter these parameters:
the start time and frequency.
During a filter cycle, pumps run
for one minute to purge the
plumbing, then Pump 1 runs
for the programmed number
of hours.
Press Prog. key a third time.
The display will show FSxx, with
"xx" representing the starting
hour.
Use Up or Down key to
change setting.
Program key
Use Light key to display time
or enter Programming menu
by pressing and holding key. In
Programming mode,
the following parameters can
be set: time, filter cycle start
time, filter cycle frequency, and
temperature unit.