Smart Winter Mode
Our Smart Winter Modeprotects your system from
the cold by turning pumps on several times
a day to prevent
water from freezing in pipes.
When the system detects a risk of freezing,
the Smart Winter Mode
protection kicks in and remains active till a
full 24 hours has passed
without the risk
of freezing.
The “Smart Winter Mode” indicator lights up
when the Smart Winter
Mode is on.
Spaside Messages
An internal hardware error has been detected in the spapack
Contact your local dealer
Temperature sensor malfunction
This error will occur when a problem with the temperature sensor exists.
Contact your local spa dealer
Water has exceeded 108F at the temperature sensor.
The heater, pump and accessory will be deactivated until the water
cools. Be sure to check the actual water temperature with an accurate
thermometer.
DO NOT ENTER SPA WATER!!
The spa water has exceeded 119F at the high-limit sensor.
The heater will deactivate while the pump and accessory will still
operate. The blower (if equipped) can be activated to help cool the
water. Water must be below 119F and power must be reset to clear the
“HL” error
DO NOT ENTER SPA WATER!!
1. A dirty spa filter can also cause a restricted flow of water, be sure the
filter is cleaned regularly and ensure all water shutoff valves are open.
2. If the system has been operating normally until now, the pump may
be overheating the spa. Refer to “Programing Filtration” on page 18 and
reduce the duration and/or number of cycles per day.
3. If you’ve eliminated items 1 & 2 as problems, the high-limit sensor
may have malfunctioned.
Contact your local spa dealer
The system did not detect any water flow while the main pump was
running.
Ÿ Make sure that the low-level programming has been properly set,
with or without circulation pump (depending on your system
configuration)
Ÿ Make sure water valves are open and that water level is high enough
Ÿ Check and remove anything obstructing the filter
Ÿ With heater pump ON the pressure switch must be a CLOSED circuit
Pressure/Flow Switch systems ONLY: Pressure/flow switch is not
opening when system expects it to be open
Ÿ Make sure that the low-level programming has been properly set,
with or without circulation pump (depending on your system
configuration)
Ÿ With heater pump OFF the pressure switch must be a OPEN circuit
17