Troubleshooting
Therapy Jet Not Operational
Water Shut-Off Valves are Closed - Open Shut-Off valves.
Dirty Filter - Clean or replace filter.
Jets Not Properly Adjusted - Adjust Jets properly.
Diverter Valve Not Properly Adjusted - Adjust diverter valve properly.
Thermal Overload Tripping - Check for restricted flow of water.
Water Leaks
Spa Overfilled - Adjust water level.
Too Many People in the Spa - Adjust water level.
Drain-Valve Left Open - Close drain valve.
Couplings or Unions Loose - Tighten or contact your local dealer.
Pump Seal Leaking - Contact your local dealer.
Plumbing / Connections Leaking - Contact your local dealer.
Water Leaking from Spaside Control - Contact your local dealer.
Water in Air Blower Plumbing - Contact your local dealer.
No Heat
Temperature Not Set Correctly - Adjust Set Point.
Over or High Temperature Protection On - Refer to Spa Side Messages
Current Limiting On - 120V Systems will not heat if High Speed or Blower is on.
Contact your local dealer.
No Power - Reset breaker at service panel.
Low Water Flow - Clean or Replace filter.
System is in Rest Mode - Refer to Modes on page 19.
Light Not Operation
Light Bulb Defective - Replace bulb or contact your local dealer.
Reflector has Fallen Off - Replace deflector or contact your local dealer.
Light Not Plugged-In - Plug in the Light.
High Heat
Filter Cycles Running Too Long - Adjust filter cycles down.
Temperature Set Too High - Adjust Set Point.
High Ambient Temperature - Remove spa cover.
GFCI Breaker Trips Occasionally
Lightning / Electrical Storm or Power Surge
- Reset GFCI Breaker.
NOTE: The GFCI breaker must be properly installed by a licensed electrician.
GFCI Breaker Trips Immediately
Defective Component or Improper GFCI Breaker Installation - Contact a qualified
service technician or the factory for assistance.
Temp/Hi-Limit sensor not connected - Connect Temp/Hi-Limit to P38 on PCB