3
10
in.k300 TechBook
Setting economy duration*
The display will show Edxx, “xx” representing the duration in
hours of the economy mode. Use the arrow keys to adjust
the hour. Use the Light key to jump to the next parameter,
temperature unit.
24 = continuous economy
Setting temperature unit
Water temperature can be displayed in either Fahrenheit (°F)
or Celsius (°C). The display will show °F or °C.
Use the arrow keys to change the setting.
Use the Program or Light key to save all the parameters.
Smart Winter Mode
Our Smart Winter Mode protects your system from
the cold by turning pumps on several times a day
to prevent water from freezing in pipes.
The “SWM” indicator lights up when freezing is
detected and flashes when the purge is active.
Water temperature regulation
Every 15 to 90 minutes the pump will run to ensure
accurate water temperature readings as well as avoid
heater activation in dry conditions. After verifying pump
activation and taking a water temperature reading if
required, the system automatically turns the heater on to
reach and maintain water temperature at Set Point.
Indicator flashes when taking water
temperature reading.
Cooldown
After heating the spa water to the desired Set Point,
the heater is turned off, but its associated pump
(Pump 1 low-speed or CP) remains on for
a predetermined period of time to ensure adequate
cooling of the heating element, prolonging its useful life.
*
Note that the parameters for the economy mode settings are associated to specific low level configuration of the system that are not
present in all software revisions.