133
MAINTENANCE
Every 50 Hours
Inspecting the Bucket Stoppers
(bolts / nuts)
WARNING
Before performing maintenance or
repairs under the machine, set all working
equipment against the ground or in the
lowermost position.
1. Park the machine on firm, level ground
and remove the bucket.
2. Retract the bucket cylinders and lift arm
cylinders to the minimum length.
3. Inspect the adjusting bolts (1) and lock
nuts (2) for bending, denting, deformation
and looseness.
4. If there are any irregularities with the
adjusting bolts (1) and lock nuts (2).
Refer to page 140, “Adjusting or Replacing
the Bucket Stoppers (bolts/nuts)”.