*SETTING COFFEE FLOWING AND HOT WATER
BREWING TIME
1. Single cup: Press auto coffee button (single) 3s, the indicator will be
flashing, enter the flowing setting, machine start to work, count flowing
according to personal preference, release the button to finish setting;
2. Double cup: Press auto coffee button (double) 3s, the indicator will be
flashing, enter the flowing setting, machine start to work, count flowing
according to personal preference, release the button to finish setting;
3. Hot water: Press ‘hot water’ coffee button 3s, the indicator will be flashing,
then press button again and begin to count time, you can stop and release
the button as your favorite.
4. Reset: Under the machine soft shutdown, press auto coffee button single
and double at the same time 3s, after two indicator is flashing, the machine
restore default setting;
Note: Under ‘stand by’ mode to setting.
Default setting: Single cup: 30ml; Double cup: 60ml; Hot water:5s.
Put the coffee powder into porta filter to make espresso when setting
(25s with 30ml coffee as standard), to make setting is more accurate.
*CLEAN AND MAINTENANCE
1. The machine has to be switched off and cooled down before cleaning.
2. Clean housing with damp cloth or neutral detergent.
Note: Do not use abrasive sponges and detergents or solvents.
Do not immerse the machine into water.
3. Clean steam outlet, confirm there is no blockage.
4. Clean outlet and the seal under the group head with brush;
5. Clockwise rotation to remove porta filter holder, pour out coffee grounds,
and then clean it.
*CLEANING MINERAL DEPOSITS (STEAM PART)
1. The machine will accumulate lime scale deposits after use a period time,
in order to ensure the normal use of machine, you need descale the
machine every 30 days;
2. Under the condition of cut off electricity, open the steam water outlet
valve clockwise with a wrench, and then close the valve after draining the
water in the steam boiler (Figure 12)
3. Pour water and descale in water tank (about 1L, water and descale ratio is
4:1, follow the instruction of descale. Please use “household descale”, or
you can use the citric acid replace descale (water and citric acid ratio is
100:3);
4. Connected power, turn on main power button and power button, machine
will automatic pumping water and preheating;
5. Turn off the main power button and cut off electricity after 3min, open the
steam water outlet valve clockwise with a wrench, and close the valve
valve after draining the stored water.
Note: Wait about 1 hour until water cool down before operating..
6. Use soft water or pure water and repeat above steps 1 time to make sure
the pipe has been cleaned;