EasyManua.ls Logo

Genelec 8331A - Signal Processing and Control Specifications; Analog and Digital Input Characteristics; Control Network and Crossover Points; GLM Software Calibration Features

Genelec 8331A
8 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Genelec Document D0131R001 Copyright Genelec Oy 4.2017. All data subject to change without prior notice.
www.genelec.com
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In China please contact:
Beijing Genelec Audio Co.Ltd
B33 - 101
Universal Business Park
No. 10 Jiuxianqiao Road
Chaoyang District
100015 Beijing, China
Phone +86 (10) 5823 2014, 400 700 1978
Email genelec.china@genelec.com
In Sweden please contact:
Genelec Sverige
Ellipsvägen 10B
P.O. Box 2306
S-127 02 Skärholmen
Phone +46 8 449 5220
Fax +46 8 708 7071
Email info@genelec.com
* The notch and shelving lters adjustments, AutoCal
TM
and GLM
TM
manual system calibration features are part of the Genelec Loudspeaker Manager (GLM
TM
) software
8331A
Analog signal input connector XLR female, balanced 10 kOhm
Maximum analog input signal
Analog input sensitivity (100 dB SPL at 1 m)
Analog input sensitivity control
pin 1 gnd
pin 2 non-inverting
pin 3 inverting
+24.0 dBu
-6 dBu
Adjustable from +36 to -6 dBu
Digital signal input connector XLR female 110 Ohm
Digital signal output / Thru connector XLR male 110 Ohm
Digital audio input
Word length
Sample rate
Digital input sensitivity (100 dB SPL at 1 m)
Digital input maximum attenuation
AES/EBU Single Wire
AES/EBU Single Wire
16 - 24 bits
32 - 192 kHz
-30 dBFS
42 dB
Control network
Type
Connection
Proprietary GLM™ network
2 RJ45, CAT5 cables
Crossover frequencies
Bass/Mid
Mid/Treble
500 Hz
3 kHz
GLM
TM
software frequency response adjustment*
Parametric notch filters
Shelving filters
16
2 LF and 2 HF
System room response calibration Genelec GLM AutoCal™, GLM
TM
manual, Stand-alone*