SPECIFICATIONS
MaxTmum Surge Watts ................. 13,500 watts
Continuous Wr_L-l:ageCap_ci_/ ............ 7,500 watts
Power F_c_or ................................ 1,0
R_ted Maximum Con_TnuousAC Lo_d Current:
At 120Vol_s ......................... 62,5 Amps
At 240 Vol_s ......................... 31,2 Amps
Phase .................................. I_hase
R_ted Frequency ......................... 60 Hertz
Fuel Tank C_padty .................... 7 U,S, gallons
ShTppTngWeighc .......................... 240 Ibs,
GENERAL HAINTENANCE
RECOMMENDATIONS
The Owner/Operecor is responsTble for makTng sure _h_t
_11perTodTcmaTncenancetasks are completed on _ cTmely
b_Ts; chic all dTscrep_ncies are corrected; _nd that the uniC
is kept cle_n and properly stored, NEVER operate a
damaged or defective genera(;or,
Engine Maintenance
See engine owner's manual for instructions,
CAUTION
KEEPOUT OF REACH OF CHILDREN, DON'T
POLLUTE.CONSERVERESOURCES,RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consis_ of keeping the unit clean
_nd dry, Operate _nd score _he unic in _ cle_n dry
environment where it will noc be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slo_s in_he generator muse noC become clogged with snow,
leaves or _ny other foreign m_teri_l.
NOTE: DO NOT use garden hose to cle_n generator.
Water can enter engine fuel system and c_use problems. In
_ddi_ion, if w_ter enters generator _hrough cooling _ir slots,
some of _he w_ter will be re_ined in voids _nd crec_ of
_he rotor and sta_or winding insul_ion,W_er _nd dir_
buildup on the generecor internal windings will eventually
decrease the insulation resistance of these windings,
Battery Maintenance
O_her _h_n float charging,described elsewhere, no
maintenance is recIuired for the b_t_ery, Keep the battery
_nd terminals cle_n _nd dry,
IMPORTANT: B_ery charging should be performed in a
dry Ioc_cion, such as inside _ garzge.
To Clean the Generator
Use damp clod_ to wipe exterior surfaces clean.
CAUTION
Use soft brisde brush to loosen c_ked on dir_ or oil.
Use vacuum cleaner to pick up loose dirt.
Use low pressure _ir (not co exceed 25 psi) to blow
w_y dir_, Inspect cooling _ir slots _nd opening on
generecor.These openings muse be kept cle_n and
unobstructed,