3.1 MAINTENANCE SCHEDULE
Operation Maintenance Daily Every Season Every Season Every Season
Check Oil Level
9
Service Air Pre-Cleaner
9**
Change Oil and Oil Filter‡
9*
Clean Spark Arrestor Screen
9
Adjust Valve Clearance
9
Service Air Cleaner
9**
Replace Spark Plugs
9
‡ Change oil after first 8 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air cleaner parts if very dirty..
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
Model .................................................................................. GPS 12500
Model # .................................................................................004451-1
Rated Max. Power .....................................................................12.5 kW
Surge Power ...........................................................................18.75 kW
Rated AC Voltage ......................................................................120/240
Rated Max AC Load
Current @ 240V .................................................................52.0 Amps
Current @ 120V ...............................................................104.0 Amps
Rated Frequency ..................................................... 60 Hz @3600 RPM
Phase ................................................................................ Single Phase
Rated DC Voltage ...................................................................... 12 Volts
Rated Max DC Load Current @ 12 Volts ............................. 10 Amperes
3.2.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM .......................................................30
Displacement ............................................................................... 990cc
Spark Plug Type ...................................Champion RC14YC or Equivalent
Spark Plug Gap ............................................... 0.040 inch or (1.01 mm)
Gasoline Capacity .......................................................... 16 U.S. gallons
Oil Type....................................................Summer – SAE 30 or 10W-30
Winter – Synthetic 5W-20 or 5W-30
Oil Capacity
w/ Filter Change .......................................................................1.5 Qts.
w/o Filter Change .....................................................................1.2 Qts.
Run Time/Fuel Consumption-1/2 Load .....10 Hours/1.6 gallons per hour
3.3 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value
from the warranty, the operator must maintain the generator as
instructed in this manual.
Some adjustments will need to be made periodically to properly
maintain the generator.
All adjustments in the Maintenance section (3) of this manual
should be made at least once each season. Follow the requirements
in the "Maintenance Schedule" chart on page 14.
NOTICE:
Once a year you should replace the spark plug and replace the
air filter. A new spark plug and clean air filter assure proper fuel-
air mixture and help your engine run better and last longer.
3.3.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry.
Operate and store the unit in a clean dry environment where it will
not be exposed to excessive dust, dirt, moisture or any corrosive
vapors. Cooling air slots in the generator must not become clogged
with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when
dust, dirt, oil, moisture or other foreign substances are visible on
its exterior surface.
Section 3 — Maintenance
Portable Generator System
13