Owner’s Manual
Light Tower
MLT6SMDS MLT6SKDS
S/N 3002908801 and above
SAVE THIS MANUAL FOR FUTURE REFERENCE
For technical assistance contact:
www.generacmobileproducts.com
Technical Support
1-800-926-9768
008615

Table of Contents

Questions and Answers

  • D
    Danielle MartinAug 9, 2025
    Why does my Generac Power Systems MAGNUM MLT6SMDS Construction Equipment have low oil pressure shutdown?
    • Y
      Yvette WilsonAug 9, 2025
      If your Generac Power Systems Construction Equipment experiences a low oil pressure shutdown, it could be due to several reasons: a low oil level (verify oil level on dipstick and add oil if needed), oil leaking from the engine (inspect the engine for leaks), or an oil pressure switch failure (refer to the OEM engine operator’s manual to identify corrective action).
  • S
    Sheila DavisAug 14, 2025
    What to do if my Generac Power Systems MAGNUM MLT6SMDS Construction Equipment cranks but won't start?
    • L
      lsmithAug 14, 2025
      If your Generac Power Systems Construction Equipment cranks but will not start, the issue might be due to a low fuel level (check fuel level in tank and verify fuel pump operation), a restricted air filter (inspect air filter for blockage; refer to OEM engine operator’s manual for additional information), or the PAS being engaged (verify PAS is off).
  • A
    Amber AshleySep 2, 2025
    What causes mast lights to be off when checking inside the control box of Generac Power Systems MAGNUM MLT6SMDS?
    • D
      Donna HamiltonSep 2, 2025
      If the mast lights are off on your Generac Power Systems Construction Equipment, and you're checking inside the control box, the issue may stem from loose lighting connections (inspect the connections inside the control box) or an incorrect generator output (check the incoming voltage to the ballast driver by checking the available voltage on the GFCI receptacle; incoming voltage should be 120V ± 5V; if voltage is incorrect, the generator may require service).
  • C
    colematthewNov 20, 2025
    Why does my Generac Power Systems Construction Equipment have a high coolant temperature shutdown?
    • A
      April MartinNov 20, 2025
      If your Generac Power Systems Construction Equipment experiences a high coolant temperature shutdown, it could be due to several factors: a low coolant level (add coolant if needed, allow engine to cool, then check coolant level in radiator; restart engine and check coolant temperature, stopping immediately if it exceeds 210 °F (99 °C)), a blockage in the radiator (inspect radiator shroud and ducting for blockage and remove any foreign matter), leakage in coolant hoses, engine block, or water pump (inspect for visible leaks and verify tension of water pump serpentine drive belt; remove load on generator and restart engine, verifying coolant temperature and shutting down immediately if it overheats), a faulty thermostat or water pump failure (contact a GMP ASD to replace), or an incorrect m...
  • Z
    zmooreNov 25, 2025
    How to troubleshoot mast lights off on Generac Power Systems MAGNUM MLT6SMDS Construction Equipment?
    • A
      Anna DudleyNov 25, 2025
      If the mast lights are off on your Generac Power Systems Construction Equipment, and you're checking outside the control box, it could be due to a few reasons: * The light fixture is too hot (allow light to cool 10–15 minutes before restarting). * Loose lighting connections (inspect the connections inside the mast junction box and each mast light housing/socket). * A damaged or loose electrical cord (inspect the mast electrical cord for damage and check the cord connections inside the control box). * A faulty fuel filter (with engine running and lights off, measure voltage and frequency at the GFCI receptacle; voltage should indicate 120VAC ± 5%, and frequency should indicate 60.7 Hz ± 5%; if both are low (

Summary

Introduction and Safety

Safety Fundamentals

Emphasizes reading the manual and outlines general safety rules and hazard definitions.

Operational Hazards Overview

Details general, fire, trailer, and fuel hazards relevant to unit operation.

Operation

Light Tower Setup and Mast Raising

Step-by-step instructions for setting up the light tower and raising the mast.

Unit Starting Procedures

Covers prestart checks, starting units via key switch or Power Zone-DLA.

Towing, Lifting, and Securing the Unit

Procedures for safely towing, lifting, and securing the unit for transport.

Maintenance

Inspection and Service Preparation

Covers daily checks, general maintenance principles, and preparing for service.

Troubleshooting

General Troubleshooting Guide

A guide to identify and fix common engine and unit issues.

Troubleshooting Light Issues

Steps to diagnose and resolve issues related to the unit's lights.

Wiring Diagrams

Generac Power Systems MAGNUM MLT6SMDS Specifications

General IconGeneral
BrandGenerac Power Systems
ModelMAGNUM MLT6SMDS
CategoryConstruction Equipment
LanguageEnglish

Related product manuals