Testing the GFCI
Test your GFCI outlet every month, as follows:
• Pushthe black*'Test" button.The red "Reset" button
should pop out, which should allow no power to reach
the outlet. Use a test lamp in each outlet to test this.
I[o_ IIP_LV_ilDZeelIJ[!]r_]:i _tI
_ AUTION! Ifthe"Reset" button does not pop
out or the test tamp remains lit when the "Reset"
button is popped out, do not use any outlets on the
circuit Call a qualified electrician.
• If the GFCI tests good, restore power by pressingthe
"Reset" button firmly until it is fully in place and locksin
that position. If the GFCI outlet does not reset
properly, do not use the outlet _ call a Generac
service center.
• If the GFCI trips by itselfat anytime, reset and test the
outlet. If the reset button does pop out when the
test button is pressed, do not use the outlet. Call
a Generac service center.
12Volt DC, I 0 Amp Receptacle
This receptacle (Figure 10) allows you to recharge a 12Volt
automotive or utility style storage battery with the battery
chargecables provided.
This receptacle can not recharge 6Volt batteries and can
not be used to crank an engine having a discharged battery.
See"Charging a Battery" on page8 before attempting to
recharge a battery.This outlet isprotected by a l0 Amp self
resetting circuit breaker.
/
10