570 SERIES
DOWN FLOW
RETURN AIR
WARM AIR
WARM AIR
DRAIN
3
3
Connect by-pass pipe to collar and humidifier cabinet. Using
holes at top and bottom of side panel discharge, pierce 2
self tapping screws through by-pass pipe.
1
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before
beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures
exceed 150 degrees F. When wiring into a multi-speed blower circuit see Step 6.
FOR INSTALLATION ON A VERTICAL
PLENUM SURFACE OF ANY
FORCED AIR FURNACE
INSTALLER: PLEASE FILL OUT AND MAIL WARRANTY CARD AFTER INSTALLATION IS
COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
INSTALLATION: The humidifier may be mounted with the 6" outlet to
the right or left by inverting the cabinet and reversing the positions of
the distributor trough and drain pan. The humidifier may be mounted
on the warm or return air plenum with equal efficiency.
See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper
supply tubing for hot water applications
2. 6" diameter galvanized by-pass pipe
3. electrical wire and wire nuts
4. current sensing relay (G.F. Model #GA50 suggested)
5. #8 self piercing sheet metal screws
FLOW-THROUGH
BYPASS HUMIDIFIER
COPPER
TUBING
PLASTIC
TUBING
Mount the self tapping saddle valve or code valve on either a cold
or a hot water pipe. A side or top mount is best to avoid clogging
from pipe sediment. Connect 1/4” O.D. tubing to the saddle valve.
Copper tubing requires a brass compression nut and brass sleeve.
Plastic tubing requires a brass insert inside the tubing, a plastic
sleeve on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN
CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.
INSTALLATION OF THIS SADDLE VALVE MUST MEET OR
EXCEED LOCAL CODES AND ORDINANCES.
4
2
1
2
GENERALAire AC SERIES
HIGH EFFICIENCY AIR CLEANER
UP FLOW
RETURN AIR
WARM AIR
DRAIN
R
R
Fresh Indoor Air Quality
FORM NO. 570-18 (FILE 15018) REV. E
6”
9-1/2”
8-7/8”
The General Aire model 570 may be installed on either the
supply or return plenum of a forced air handling system. Select
a location for the humidifier that allows for service and
maintenance. Cut out a rectangle 8-7/8” wide by 9-1/2“ tall.
Extend horizontal centerline of cut out to the adjacent plenum.
Cut a 6” hole 10” to 15from side of humidifier, on cabinet
centerline, using connecting collar as guide. The bypass is
reversible and can be mounted on the right or left side of the
humidifier.
Humidifier is self retaining. Slide top side in first, then slide
chassis down. Level chassis and install center screws. If
by-pass pipe installs to opposite side of chassis, bend clip on
chassis, remove side discharge, and reinstall discharge to
opposite side of chassis. Install remaining four corner screws.
Question and Answer IconNeed help?

Do you have a question about the GeneralAire 570 Series and is the answer not in the manual?

Summary

Installation and Setup

Installation Precautions

Safety and operational warnings for installers before starting.

Mounting and Bypass Pipe

Guidance on positioning the unit and connecting the bypass pipe.

Physical Installation Steps

Instructions for securing the humidifier chassis and components.

Plumbing and Electrical Connections

Code Valve Plumbing Instructions

Detailed steps for soldering copper pipe for the code valve.

Water Supply and Drain Setup

Connecting water supply to solenoid and routing the drain hose.

Humidistat Wiring Diagrams

Wiring schematics for electronic and manual humidistats.

Parts, Warranty, and Maintenance

Humidifier Parts List

A list of all components included with the humidifier unit.

Limited Warranty Details

Information on product warranty coverage, terms, and exclusions.

Seasonal Maintenance Guide

Procedures for cleaning and maintaining the humidifier at the end of the heating season.

Operation and Troubleshooting

Humidifier Working Principle

Explains how the humidifier operates and its key components.

Troubleshooting Common Issues

Diagnostic steps and solutions for common humidifier operational problems.

Specifications and Model Components

Performance Coverage Specifications

Data on coverage area based on construction type and performance criteria.

Packaged Component Breakdown

Lists components included with specific humidifier models (570A, 570M).

Warranty Registration

Product Registration Process

Instructions for registering the humidifier warranty online or via mail.

Summary

Installation and Setup

Installation Precautions

Safety and operational warnings for installers before starting.

Mounting and Bypass Pipe

Guidance on positioning the unit and connecting the bypass pipe.

Physical Installation Steps

Instructions for securing the humidifier chassis and components.

Plumbing and Electrical Connections

Code Valve Plumbing Instructions

Detailed steps for soldering copper pipe for the code valve.

Water Supply and Drain Setup

Connecting water supply to solenoid and routing the drain hose.

Humidistat Wiring Diagrams

Wiring schematics for electronic and manual humidistats.

Parts, Warranty, and Maintenance

Humidifier Parts List

A list of all components included with the humidifier unit.

Limited Warranty Details

Information on product warranty coverage, terms, and exclusions.

Seasonal Maintenance Guide

Procedures for cleaning and maintaining the humidifier at the end of the heating season.

Operation and Troubleshooting

Humidifier Working Principle

Explains how the humidifier operates and its key components.

Troubleshooting Common Issues

Diagnostic steps and solutions for common humidifier operational problems.

Specifications and Model Components

Performance Coverage Specifications

Data on coverage area based on construction type and performance criteria.

Packaged Component Breakdown

Lists components included with specific humidifier models (570A, 570M).

Warranty Registration

Product Registration Process

Instructions for registering the humidifier warranty online or via mail.

Overview

The GeneralAire 570 Series Flow-Through Bypass Humidifier is designed for installation on a vertical plenum surface of any forced air furnace. It operates by evaporating water into the air stream of a forced air system, utilizing the furnace's heat for evaporation. The humidifier uses minimal electrical power (2.5 watts) during operation, less than a small household light bulb.

Function Description:

The humidifier's operating principle is based on efficiently evaporating water into the air. Water flows through a strainer and is metered through an orifice to provide the correct amount of water to the evaporator pad via a distributor trough. Approximately 200 CFM of air is bypassed from the warm air plenum through the humidifier and returned to the cold air plenum. As air passes through the evaporator pad, moisture is evaporated into the air stream. Minerals are left on the evaporator pad, with a high percentage carried off with the waste water, preventing them from being blown into the air stream as occurs with atomizing humidifiers. The water supply is controlled by an electric solenoid valve, which is in series with a low-voltage humidistat. The humidistat can be wall-mounted in the living area or surface-mounted on the return air duct.

Important Technical Specifications:

  • Electrical Rating: 24 VAC / 60 Hz.
  • Power Consumption: 2.5 watts.
  • Water Flow (Standard Orifice GA4231): Approximately 3.5 GPH at 60 psi line water pressure.
  • Water Flow (Larger Orifice GA4299): Available for low water pressures (20-40 psi).
  • Dimensions (Chassis Cut-out): 8-7/8" wide by 9-1/2" tall.
  • Bypass Pipe Hole: 6" diameter, 10" to 15" from the side of the humidifier, on cabinet centerline.
  • Expected Humidity Performance Coverage (Based on Construction Type):
    • Elite 570 (12 GPD):
      • Loose (0.75 AC/H): 800 sq. ft.
      • Average (0.50 AC/H): 1200 sq. ft.
      • Tight (0.30 AC/H): 2000 sq. ft.
    • Elite 900 (17 GPD):
      • Loose (0.75 AC/H): 1115 sq. ft.
      • Average (0.50 AC/H): 1650 sq. ft.
      • Tight (0.30 AC/H): 2800 sq. ft.
    • Elite 1000 (18 GPD):
      • Loose (0.75 AC/H): 1175 sq. ft.
      • Average (0.50 AC/H): 1770 sq. ft.
      • Tight (0.30 AC/H): 3000 sq. ft.
  • Humidifier Performance Baseline Criteria:
    • Outside Design Temp: 0° F (-18° C)
    • Outside Design R.H.: 70% R.H.
    • Inside Design Temp.: 70° F (21° C)
    • Inside Design R.H.: 30% R.H.
    • Air Changes/hour (AC/H): 0.30
    • Ceiling Height: 8 ft
    • Furnace Plenum Temp.: 120° F (49° C)
    • Furnace run time for calculating sq. ft.: 8hr/1 day

Usage Features:

  • Installation Flexibility: Can be mounted on either the supply or return plenum. The 6" outlet can be positioned to the right or left by inverting the cabinet and reversing the distributor trough and drain pan.
  • Humidistat Control: The humidistat allows users to set the desired level of humidification. It is recommended to leave the knob on "HI" or "WINTER" position during operation.
  • Bypass Reversibility: The bypass can be reversed and mounted on either the right or left side of the humidifier.
  • Saddle Valve Installation: The self-tapping saddle valve or code valve can be mounted on a cold or hot water pipe. A side or top mount is recommended to avoid clogging from pipe sediment.
  • Tubing Compatibility: 1/4" O.D. copper tubing requires a brass compression nut and sleeve. Plastic tubing requires a brass insert, plastic sleeve, and brass compression nut. Important: Do not use plastic tubing on hot water or in contact with any hot plenum surface or duct.
  • Damper Control: Turn the damper knob to the winter (open) position for humidification. For summer cooling or ventilating, set the air damper on "LOW" or "SUMMER."
  • Automatic Models: Include a code valve.
  • Recommended Settings (Based on Outside Temperature):
    • -20°F (-29°C): 15%
    • -10°F (-23°C): 20%
    • 0°F (-18°C): 25%
    • +10°F (-12°C): 30%
    • +20°F (-7°C): 35%
    • +30°F (-1°C): 40%
  • Safety Precaution: Do not set relative humidity too high during cold weather, as excessive humidity can cause condensation on windows or in walls. Refer to the humidistat owner's manual for recommended settings.

Maintenance Features:

  • Annual Cleaning: At the end of each heating season, turn off water supply and electrical power. Remove the water cover, distributor trough, evaporator pad, and drain pan. Clean excessive mineral deposits from these components and the humidifier cabinet using a solution of 1/2 vinegar & 1/2 water to loosen deposits.
  • Evaporator Pad Replacement: Replace the evaporator pad (Part number GA10) yearly for peak performance.
  • Solenoid Valve Maintenance: In heavy mineral areas or if the solenoid valve malfunctions, disconnect the 1/4" water supply line. Carefully pull the strainer screen (P.N. GA4004) from the valve body (P.N. 900-6) and clean mineral deposits. If the orifice is clogged, it can be opened with a small pin. Reinsert the filter and screw the brass strainer body into the solenoid valve.
  • Leak Check: After reconnecting the 1/4" water line, turn on the water supply and check for leaks.
  • Summer Shutdown: During the summer, turn off the water supply and electrical power to the humidifier, and close the air damper.
  • Troubleshooting: A diagnostic step guide is provided for common issues such as the humidifier not operating, proper voltage but no water flow, humidifier running without furnace operation, or excessive humidity.
  • Warranty: This humidifier is warranted against defects in materials and workmanship for ten years from the date of installation, provided it is properly registered. Evaporator pads, water strainers, or metering orifices are not covered by this warranty. Defective parts will be repaired without charge, excluding removal, reinstallation, and transportation costs.

GeneralAire 570 Series Specifications

General IconGeneral
BrandGeneralAire
Model570 Series
CategoryHumidifier
LanguageEnglish

Related product manuals