13. FUNCTION LOGICS
Logic A Automatic C= from 1 to 9 d=0 E=0
Automated
system status
Inputs
Open / Close Close Stop
Safety devices
y=0
Active only for closure
y=1
Active for closing and opening
Closed
Opens and re-closes after
pause time
No effect
No effect, if active it disables the
OPEN commands
No effect
It disables the
OPEN commands
Open in pause
P=0 (immediate closure
activated) Closes immediately.
Closes immediately Stops operation
O=0 At release, if pause time
has elapsed, re-closes after 5
seconds.
I f i t r e c e i v e s a C L O S E
command while the safety
device is engaged, it saves the
command and re-closes after 5
seconds at release. The OPEN/
CLOSE command is stored in the
memory only if
P=0
At release, if pause time has
elapsed, re-closes after 5
seconds.
I f i t r e c e i v e s a C L O S E
command while the safety
device is engaged, it saves the
command and re-closes after 5
seconds at release. The OPEN/
CLOSE command is stored in the
memory only if
P=0
P=1 (timer function activated)
Recharges pause time. If held
down, it stops the count and
resumes counting at release.
O=1 Closes immediately at
release, if pause time has
elapsed, re-closes after 5
seconds.
At closure
Reverses movement to
opening
No effect Stops operation
Reverses movement to
opening
Stops operation and reverses to
opening after release
At opening
Reverses movement to clos-
ing
a
Reverses movement to closing Stops operation No effect
Stops operation and restarts
after release
a With parameter
d=2
(Open only) during the opening phase of the automated system, the OPEN input has no effect.