ENGLISH
Logic AP Automatic Step-by-Step C=from 1 to 9 d=1 E=0
Automated
system status
Inputs
Open / Close Close Stop
Safety devices
y=0
Active only for closure
y=1
Active for closing and opening
Closed
Opens and re-closes after
pause time
No effect
No effect, if active it disables the
OPEN commands
No effect
It disables the
OPEN commands
Open in pause
P=0 (immediate closure
activated) Closes immediately.
Closes immediately Stops operation
O=0 At release, if pause time
has elapsed, re-closes after 5
seconds.
I f i t r e c e i v e s a C L O S E
command while the safety
device is engaged, it saves the
command and re-closes after 5
seconds at release. The OPEN/
CLOSE command is stored in the
memory only if
P=0
At release, if pause time has
elapsed, re-closes after 5
seconds.
I f i t r e c e i v e s a C L O S E
command while the safety
device is engaged, it saves the
command and re-closes after 5
seconds at release. The OPEN/
CLOSE command is stored in the
memory only if
P=0
P=1 (timer function activated)
Recharges pause time. If held
down, it stops the count and
resumes counting at release.
O=1 Closes immediately at
release, if pause time has
elapsed, re-closes after 5
seconds
At closure
Stops the movement and opens
at next impulse
No effect Stops operation
Reverses movement to
opening
Stops operation and reverses to
opening after release
At opening
Stops the movement and closes
at next impulse
a
Reverses movement to
closure
Stops operation No effect
Stops operation and restarts
after release
a With parameter
d=2
(Open only) during the opening phase of the automated system, the OPEN input has no effect.