ENGLISH
Semi-automatic logic E C=1 d=0 E= 0
Automated
system status
Inputs
Open / Close Close Stop
Safety devices
y=0 y=1
Closed Opens No effect
No effect, if active it disables the
OPEN commands
No effect
It disables the
OPEN commands
Open Closes Closes
No effect, if active, it disables all
commands
If it receives an impulse from
the OPEN or CLOSE command,
it saves the command and
re-closes after 5 seconds at
release
If it receives an impulse from
the OPEN or CLOSE command,
it saves the command and
re-closes after 5 seconds at
release
At closure
Reverses movement to
opening
No effect Stops operation
Reverses movement to
opening
Stops operation and reverses to
opening after release
At opening
Reverses movement to
closure
a
Reverses movement to
closure
Stops operation No effect
Stops operation and restarts
after release
a With parameter
d=2
(Open only) during the opening phase of the automated system, the OPEN input has no effect.
Logic EP Stepped Semi-Automatic C=0 d=1 E= 0
Automated
system status
Inputs
Open / Close Close Stop
Safety devices
y=0 y=1
Closed Opens No effect
No effect, if active it disables the
OPEN commands
No effect
It disables the
OPEN commands
Open Closes Closes
No effect, if active, it disables all
commands
If engaged, it saves the OPEN
or Close command and, on
release it re-closes after 5
seconds
If engaged, it saves the OPEN
or CLOSE command and, on
release it re-closes after 5
seconds
At closure
Stops the movement and opens
at next impulse
No effect Stops operation
Reverses movement to
opening
Stops operation and reverses to
opening after release
At opening
Stops the movement and closes
at next impulse
a
Reverses movement to
closure
Stops operation No effect
Stops operation and restarts
after release
a With parameter
d=2
(Open only) during the opening phase of the automated system, the OPEN input has no effect.