(5) Turn on one generator, then the second. Check that the Output lights of both
generators are green.
(6) Turn LOW IDLE to “ON”.
(7) Attach load to Parallel Kit.
Note: If one generator shuts off during use,
disconnect load until it can be restarted to
avoid generator damage.
Do not overload the generators. Substantial
overloading will shut off the AC output and
may shorten the service life of the
generators.
LOW IDLE
ON OFF
50A
Note: The voltage of the parallel device is 120V, and the output current is 80A (a 50A
socket and a 30A socket). Three generators can be connected in parallel at the same
time, and the total power in parallel should not exceed 9600 peak watts.