13
Have the following tools to hand:
Screwdriver 5.5/100
Combination spanner size 18
Combination spanner size 30
Combination spanner size 36
Replacing the packing
Unscrew the union nut from the cover.
Remove the stuffing box ring.
Remove the packing.
Insert new packing.
Insert the stuffing box ring.
Screw the union nut into the cover.
Tighten the union nut to a torque of 30 Nm.
Removing Thermovit regulator
To clean the Thermovit regulator and, if necessary,
replace it with a new one proceed as follows:
Remove the 4 nuts (13) and bolts (14).
Remove the cover (4) from the body (11).
Remove the body gasket (9).
Unscrew the Thermovit regulator (7) from the
body (11).
Detach the guide ring (6) from the Thermovit
regulator.
Cleaning Thermovit regulator
Clean the Thermovit regulator with fresh water
and a clean lint-free cloth.
Clean gasket seating surfaces.
Checking the component parts for damage
Check the removed parts for visible signs of
wear or damage.
Discard and replace any damaged part.