Original Installation &
Operating Manual
850691-00
Level Electrodes
NRG 16-50
NRG 17-50
NRG 19-50
EN (USA)
English

Table of Contents

Other manuals for GESTRA NRG 17-50

Questions and Answers

  • S
    santossamanthaAug 11, 2025
    What to do if hot steam escapes from GESTRA NRG 17-50?
    • N
      Natalie GarciaAug 12, 2025
      If hot steam escapes from GESTRA Measuring Instruments, immediately reduce the boiler pressure to 0 psi (0 bar) and verify the pressure before unscrewing the level electrode. Ensure the level electrode is only removed when the boiler pressure is at 0 psi (0 bar).
  • S
    Samantha MartinezAug 17, 2025
    How to prevent burns from a hot GESTRA Measuring Instruments level electrode?
    • S
      Steven BuchananAug 17, 2025
      To prevent burns from a hot level electrode on GESTRA Measuring Instruments, always allow the level electrode to cool down before starting any installation or maintenance work. Only remove level electrodes after they have cooled down completely.
  • C
    christineedwardsAug 23, 2025
    What to do if LED alarm 1 or 2 and Diagnosis LED 3 are illuminated on GESTRA Switch?
    • J
      Joel QuinnAug 23, 2025
      If the LED alarm 1 or 2 and Diagnosis LED 3 are illuminated on your GESTRA Switch, and pressing and holding down key 1 or 2 doesn't resolve the issue, it could be due to a malfunction in the processor or a stand-by fault. Refer to the operating instructions for the logic unit SRL and consider replacing the level switch. It could also indicate an internal voltage fault, in which case you should replace the level switch.
  • R
    Rebecca MunozAug 30, 2025
    Why is the Diagnosis LED 3 flashing on my GESTRA Switch?
    • M
      Monica HernandezAug 30, 2025
      If the Diagnosis LED 3 is flashing on your GESTRA Switch, it may be due to interference voltage causing a malfunction, or the boiler earth may be without PE. To resolve this, provide screen and earthing, and connect the boiler with PE.
  • S
    Sarah OlsonSep 4, 2025
    What to do if LED alarm 1 and diagnosis LED 1 are illuminated on GESTRA Switch?
    • M
      Michael SandersSep 4, 2025
      If LED alarm 1 and diagnosis LED 1 are illuminated on your GESTRA Switch, and pressing and holding down key 1 doesn't resolve the issue, it could indicate a malfunction in the level electrode or level switch, faulty wiring, or a faulty measuring voltage. Check the wiring, measure electrode voltages, clean and, if necessary, exchange the level electrode, and exchange the level switch.