Output | 4-20 mA |
---|---|
Communication Protocols | Modbus RTU |
Display | LCD |
Enclosure | NEMA 4X |
Relay | SPDT, 5 A |
Analog output | 4-20 mA |
Digital Input | 2 |
Digital Output | 2 |
Connects an external counter for pulse output.
Links two batch controllers for sequential operation.
Configures a bypass line for reduced flow rate at a set batch percentage.
Detects missing sensor signal or valve leaks/stuck open.
Linear output from 4 mA to 20 mA indicating batch progress.
Outputs 4-20 mA to control a valve for filling or flow rate adjustment.
Describes basic functions for on/off control, pulse output, and alarms.
Details advanced features like overrun compensation and custom pulse outputs.
Explains the standard operation menu for batch control and viewing.
Accesses critical display setup and output parameters with security.
Contains seldom-accessed setup and display features for minor adjustments.
Sets the measurement units for batching (e.g., Gallons, Liters).
Configures the time base for flow rate display (seconds, minutes, hours).
Calculates a custom flow sensor/batch K-Factor for precise batching.
Sets the K-Factor for batching, representing sensor pulses per unit.
Sets the measurement units for the totalizer.
Sets the K-Factor for the totalizer.
Displays or sets the last calibration date.
Adjusts the display contrast for better readability.
Sets the decimal places for flow rate display.
Sets the decimal places for totalizer display.
Enables or disables the VIEW menu lock with an access code.
Selects between Simple and Advanced operation modes.
Configures the pulse output operation mode (End of Batch or Totalizer).
Sets the overrun compensation mode to Manual or Auto.
Configures the function of the option contact (e.g., Two Stage, Alarm).
Configures the delay time for the missing signal alarm.
Sets the current output mode (Batch Completion, Valve Control, End of Batch).
Sets the batch display count direction (Up or Down).
Details general specifications like sensor compatibility and accuracy.
Provides enclosure details like rating, dimensions, and materials.
Describes display type, update rate, contrast, and alarm annunciators.
Specifies totalizer features like resettable and non-resettable digits.
Lists power requirements, contact ratings, and current output specifications.
Details operating and storage temperatures, humidity, and altitude.
Lists agency approvals and manufacturing standards.
Lists parameters and their default settings for the VIEW menu.
Sets the measurement units for batching (e.g., Gallons, Liters).
Configures the time base for flow rate display (seconds, minutes, hours).
Optional volumetric calibration for custom K-Factor calculation.
Sets the K-Factor for batching, representing sensor pulses per unit.
Sets the measurement units for the totalizer.
Sets the K-Factor for the totalizer.
Displays or sets the last calibration date.
Adjusts the display contrast for better readability.
Sets the decimal places for flow rate display.
Sets the decimal places for totalizer display.
Enables or disables the VIEW menu lock with an access code.
Selects between Simple and Advanced operation modes.
Configures the pulse output operation mode (End of Batch or Totalizer).
Sets the overrun compensation mode to Manual or Auto.
Configures the function of the option contact (e.g., Two Stage, Alarm).
Configures the delay time for the missing signal alarm.
Sets the current output mode (Batch Completion, Valve Control, End of Batch).
Sets the batch display count direction (Up or Down).