EasyManua.ls Logo

Gianni DG-15 User Manual

Default Icon
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DG-15 & DG-15LD
Digital Keypad
Operation Manual
I. Specifications
DG-15
DG-15WP
12 VDC
Operating Voltage
DG-15LD
12~24 VDC
DG-15
DG-15WP
Pull in: 50 mA Holding: 10mA /12VDC
Pull in: 70 mA Holding: 40mA /12VDC
Current Draw
DG-15LD
Pull in: 100 mA Holding: 60mA /24VDC
Keypad
12 buttons (0~9,,)
LED Status Indication 3 LED indicators display (Red/Yellow/Green)
Input
1 contact for Request-To-Exit button
1 contact for door reed switch
Output 2 relays (Dry contacts: N.O./N.C./Com.)
Relay Strike Time 01~99 seconds or Toggle Mode (00)
Relay Electric Current 3A/120VAC , 3A/24VDC
Memory Volume
20+1 PINs (01~021)
Relay 1 is controlled by user 01~20
Relay 2 is controlled by user 21
Sign: Relay1(30); Relay2(31)
EPROM
Non-volatile memory allows remaining all setting codes in the event
of total power failure.
Ambient Humidity 0%~95% (Non-condensing)
Operating Temperature -20°C~+70°C
II. Status Indication
Green On Power on, Stand by
Red On Relay 1 active
LED
Yellow On Relay 2 active
1 Beep Valid key press
2 Beeps Enter, exit setting mode
3 Beeps Incorrect operation
Beep
5 Beeps Master Code back to 12345 (Cleared settings)
III. Operation Instruction
Jumper Setting
4or5
RESET
Master Code reset to
default value"12345"
Reset
Normal
4 or 5 digit setting
4 digit
5 digit
1. Default value: “1234” for 4 digits, “12345” for 5 digits
It’s suggested to clear all stored codes prior to new setting.
2. Master Code reset to default value”12345”:
a. Insert the jumper into 1-2 (5 beeps)
b. Master Code reset to default value
Copyright All Rights Reserved.
P-MU-DG15 Ver. I Publish:2010.08.12 Page: 1/ 3
Question and Answer IconNeed help?

Do you have a question about the Gianni DG-15 and is the answer not in the manual?

Gianni DG-15 Specifications

General IconGeneral
BrandGianni
ModelDG-15
CategoryKeypad
LanguageEnglish

Summary

Digital Keypad Operation Manual Specifications

Operating Voltage

Specifies the operating voltage for DG-15 and DG-15LD models.

Current Draw Specifications

Details the pull-in and holding current for DG-15, DG-15WP, and DG-15LD.

Keypad and LED Indicators

Describes the 12-button keypad and 3-LED status indication.

Input and Output Terminals

Details input contacts for Request-To-Exit and door reed switch, and output relays.

Relay Settings and Memory

Covers relay strike time, electric current ratings, memory volume, and EPROM.

Environmental Operating Conditions

Specifies ambient humidity and operating temperature ranges.

Status Indication Guide

LED Status Meanings

Explains the meaning of Green, Red, and Yellow LED indications.

Beep Code Interpretation

Defines the operational meaning of 1, 2, 3, and 5 beeps.

Operation Instructions and Settings

Jumper Setting for Configuration

Guides on jumper settings for digit length and master code reset.

Entering Setting Mode

Instructions on how to enter the device's setting mode using the master code.

PIN Management

Procedures for adding and deleting PINs, and managing relay control.

Relay Strike Time Configuration

Steps to set the relay strike duration or toggle mode.

Master Code Management

Procedure to change the master code for security.

Wiring Diagram and System Components

Wiring Connections

Illustrates connections for power supply, electric locks, and inputs/outputs.

Component Protection Note

Advises on using varistors or diodes to protect against back EMF.

Product Warranty Information