EasyManua.ls Logo

Giant PV1 - Wiring

Giant PV1
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION INSTRUCTIONS
Wiring
This water heater uses an external electrical source
for power. It must be electrically grounded in accor-
dance with all local codes or, in the absence of local
codes, CSA C22.1 Canadian Electrical Code, in
Canada and/or the National Electrical Code, ANSI/
NFPA 70, in the United States. Failure to properly
ground this water heater can result in property dam-
age, personal injury or death.
Before lighting your water heater, check that all of the
wires have been installed correctly (see Figure 14).
Make sure that none of the wires are grounded, have
split or are broken. Verify that all wiring connections
are properly secured, as there is a possibility that they
have become loose during transportation. If any of the
original wiring needs replacing, use only 18AWG-
type or greater wire that is approved for 221
o
F (105
o
C).
WARNING
AVERTISSEMENT
DANGER
Blower Unit / Unité de Ventilation
High Limit Switch /
Interrupteur Haute
Limite
Vacuum Switch (N.O.) /
Interrupteur de Pression
Negative (N.O.)
Yellow / Jaune
Red / Rouge
Power Cord /
Cordon d'Alimentation
White / Blanc
Black / Noir
Green / Vert
Black / Noir
White / Blanc
Green / Vert
Blue / Bleu
Yellow / Jaune
Red / Rouge
Yellow / Jaune
Blue / Bleu
Hot Surface Igniter /
Allumeur à Élément
Chauffant
Flame Sensor /
Détecteur de Flamme
Flammable Vapor Sensor /
Détecteur de Vapeur Inflammable
Gas Control / Contrôle au gaz
White / Blanc
Black / Noir
Green / Vert
High Limit Switch /
Interrupteur Haute Limite
(Access Door/Porte
D'accès)
M
5
3
4
1
6
2
5
3
4
1
6
2
Blower Unit
High Limit Switch
Vacuum Switch (N.O.)
Yellow
Red
Power Cord
White
Black
Green
Black
White
Green
Blue
Yellow
Red
Yellow
Blue
Hot Surface Igniter
Flame Sensor
Flammable Vapor Sensor
Gas Control
White
Black
Green
High Limit Switch
(Access Door)
M
5
3
4
1
6
2
5
3
4
1
6
2
Unité de Ventilation
Interrupteur Haute
Limite
Interrupteur de Pression
Negative (N.O.)
Jaune
Rouge
Cordon d'Alimentation
Blanc
Noir
Vert
Noir
Blanc
Vert
Bleu
Jaune
Rouge
Jaune
Bleu
Allumeur à Élément
Chauffant
Détecteur de Flamme
Détecteur de Vapeur Inflammable
Contrôle au gaz
Blanc
Noir
Vert
Interrupteur Haute Limite
(Porte D'accès)
M
5
3
4
1
6
2
5
3
4
1
6
2
Wiring Diagram
for Models UG40, UG50, UG60