System 3000
Electronic switching insert
Electronic switching insert
Order no.: 5405 00
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.
Risk of destruction if the set operating mode and load type do not match. Set correct operating
mode when connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
2 Intended use
Operation with suitable cover
Mounting in appliance box according to DIN 49073
Operation with neutral conductor
Switching of incandescent lamps, HV halogen lamps, electronic or inductive transformers
with halogen or LED lamps, switchable or dimmable HV-LED or compact fluorescent
lamps, electrothermal actuators in combination with room temperature controller covers
Operation without neutral conductor
Switching of incandescent lamps, HV halogen lamps, electronic or inductive transformers
with halogen or LED lamps, dimmable HV-LED or compact fluorescent lamps
Product characteristics
Switch-on via bulb-preserving soft start
Connection of extensions possible
Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
Electronic over-temperature protection
Flickering of the connected lamps through centralised pulses from the power stations.
This does not represent any defect in the device.
Operation with neutral conductor
Device is powered via phase conductor and neutral conductor , therefore there is no lead-
ing edge phase control or trailing edge phase control.
Operation without neutral conductor
Device is powered via the phase conductor and the connected load and therefore works
in the leading edge phase control or trailing edge phase control principle
Automatic or manual setting of the suitable operating mode for the load
Display of the set operating mode by means LED
Brief flickering upon load detection possible. No operation is possible during load detec-
tion.