5
5.0 ADDITIONAL INFORMATION
© Dimplex Boilers 2008
5.1 BOILER LOGBOOK
The logbook is included inside the Installation instructions. This
logbook should be completed by your installer to verify that
the correct installation and commissioning procedure was
followed.
Failure to complete the logbook may result in difficulties
should a problem arise with your appliance during the
guarantee period.
This logbook forms part of the industry’s Benchmark code of
practice for the installation, commissioning and servicing of
central heating systems.
All CORGI registered installers carry a CORGI identification card
and have a registration number. You can check your installer is
registered by telephoning 0870 4012300 or writing to:-
1 Elmwood
Chineham Business Park
Crockford Lane
Basingstoke
RG24 8WG
or check online at www.corgi-gas-safety.com
These appliances meet the requirements of;
Gas Appliance Directive 90/396/EEC
Efficiency of Hot Water Boilers Directive 92/42/EEC
Low Voltage Directive 92/42/EEC
Electromagnetic Compatibility Directive 92/31/EEC
Type test certified by:- Notified Body 0087 (Pin 87BT49).
Product/Production certified by:
Notified Body 0086.
For GB/IE only.
5.2 GENERAL CARE
The front panel should be cleaned with a damp cloth and mild
detergent. Do not use abrasive cleaners.
5.3 ROUTINE SERVICING
To ensure continued efficient operation of the appliance, it is
recommended that it is checked and serviced as necessary at
regular intervals. The frequency of servicing will depend upon
the particular installation conditions and usage but in general
once a year should be adequate. It is law that any service work
must be carried out by a competent person such as British Gas
or other CORGI Registered personnel.
5.5 PLUMING FROM TERMINAL
Like all condensing boilers this appliance will produce a plume
of condensation from the flue terminal. This is due to the high
efficiency and hence low flue gas temperature of the boiler. It
is normal and not a fault indication.
The boiler is fitted with a condensate trap.
The condensate drain point must not be modified or blocked
(see section 7.6 of the installation manual).
5.4 EMERGENCY
WARNING - If a gas leak is suspected or exists, turn the gas
OFF at the incoming mains (adjacent to the meter), Do not
operat
e any electrical switches. Do not operate any
electrical appliances. Open al
l
l windows and doors. Do not
smoke. Extinguish all naked lights. Phone the Transco 24
hour emergency
n
number immediately on 0800 111 999
(Do not call from a mobile phone).
For short or long periods
Switch the programmer and/or room thermostat switch to the
OFF
position.
NOTE:
The appliance is fitted with a frost protection device In
the event of very cold conditions. Providing there is mains
power supply to the appliance, the frost protection mode is
integral. If the system temperature falls below 5°C then the
boiler will fire on its minimum setting until a flow temperature
of 30°C is reached. Further protection can be incorporated by
using a system frost thermostat.
The pump will automatically operate for 1 minute in every 24
hours to prevent sticking.
5.6 TO TURN THE BOILER OFF
In the event of overheating, the boiler will shut down and the
digital display will show ‘1’. Allow the boiler to cool, then
briefly turn the CH control knob fully anti-clockwise to the
RESET/STANDBY position and then back to ‘ON’ within two
seconds.
If the fault persists, consult a CORGI Registered installer.
5.7 BOILER OVERHEAT PROTECTION
Glen Dimplex Boilers Limited is continually improving its products and therefore reserve the right to change product specifications without prior notice.
Errors & omissions excepted.
Part No: 751254 - Issue 4 - 7/07/10
Glen Dimplex Boilers
Stoney Lane
Prescot
Merseyside. L35 2XW
For all telephone enquiries call:
0844 371 2222
website:
www.glendimplexboilers.com
Part of the Glen Dimplex Group
SALES AND SERVICE HELPLINE: 0844 371 1111

Other manuals for Glen Dimplex Combi 30

Question and Answer IconNeed help?

Do you have a question about the Glen Dimplex Combi 30 and is the answer not in the manual?

Summary

Using the Glen Dimplex Combi Boiler

Control Panel Overview

Details the components and functions of the boiler's control panel for operation.

System Pressure Gauge Explanation

Explains the system pressure gauge, normal range, and issues related to pressure.

Central Heating Timer Operation

Describes the central heating time clock operation and override switch settings.

Central Heating Temperature Adjustment

How to increase the central heating temperature using the control knob.

Domestic Hot Water Temperature Adjustment

How to increase the domestic hot water temperature using the control knob.

Comfort Mode and Economy Mode

Explains the Comfort mode for preheating hot water and switching to economy mode.

Central Heating Temperature Display

Describes display behavior when adjusting central heating temperature set points.

Domestic Hot Water Temperature Display

Describes display behavior when adjusting domestic hot water temperature set points.

Re-pressurising the Heating System

Step-by-step guide on how to re-pressurise the heating system using the filling loop.

Troubleshooting Glen Dimplex Combi Boiler Issues

Step-by-Step Troubleshooting Guide

A flowchart guide to diagnose and resolve common boiler operational problems.

Glen Dimplex Combi Boiler Safety Information

General Safety Guidelines and Child Supervision

General safety precautions for appliance use and warnings regarding children.

Gas Safety Installation and Use Regulations

Legal requirements for gas appliance installation by competent persons and compliance.

Electrical Supply and Connection Details

Details electrical supply, earthing, and connection methods for the appliance.

Clearances and Ventilation Requirements

Specifies required clearances around the boiler and ventilation for installation.

Glen Dimplex Combi Boiler Error Codes

Error Code 1: Overheated Appliance

Details error code 1, reasons for overheating, and troubleshooting actions.

Error Code 4: No Flame Signal

Details error code 4, reasons for no flame, and troubleshooting actions.

Error Code 5: Flame Loss

Details error code 5, reasons for flame loss, and troubleshooting actions.

Error Code 6: Temporary Overheating

Details error code 6, reasons for temporary overheating, and troubleshooting actions.

Error Code 7: Flue Over Temperature

Details error code 7, reasons for flue over temp, and troubleshooting actions.

Error Code 11: Flame Simulation

Details error code 11, reasons for flame simulation, and troubleshooting actions.

Error Code 41: Water Flow Failure (Short Period)

Details error code 41, reasons (low pressure/sensors), and troubleshooting actions.

Error Code 42: Water Flow Failure (Dry Run)

Details error code 42, reasons (low pressure/dry run), and troubleshooting actions.

Additional Glen Dimplex Combi Boiler Information

Boiler Logbook Importance and Requirements

Information about the logbook, its importance for installation verification and warranty.

General Care and Cleaning Instructions

Instructions on how to clean the boiler's front panel and recommended cleaning agents.

Routine Servicing and Legal Requirements

Recommendations for regular servicing to ensure efficient operation, legal requirements.

Emergency Gas Leak Procedure and Contacts

Critical safety advice for gas leaks, including emergency contacts and actions.

Condensation Plume and Drain Explanation

Explanation of the condensation plume from the flue terminal and condensate trap.

Turning the Boiler Off and Frost Protection

Instructions on how to turn off the boiler for short or long periods and frost protection.

Boiler Overheat Protection and Reset

Describes the overheat protection mechanism and the reset procedure.

Glen Dimplex Combi 30 Specifications

General IconGeneral
Fuel TypeNatural Gas
Output30kW
FuelNatural Gas
MountingWall
CH Output (kW)30kW