13
105569
OWNER’S MANUAL
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information
above.
2. Make sure manual shutoff valve is
fully open.
3. Turn control knob clockwise
to the OFF position (see Figure 18).
4. Wait five (5) minutes to clear out any
gas. Then smell for gas including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation at left. If you don’t smell
gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT/IGN position.
Press in control knob for five (5) sec-
onds (see Figure 18).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
6. Release control knob pressure and
turn clockwise to OFF.
7. Press in control knob and turn back
to PILOT/IGN. This should cause
the piezo ignitor to spark and light
the pilot gas. If needed, repeat steps
5 through 7 until pilot lights.
Note:
If pilot does not stay lit, refer
to Troubleshooting, pages 15
through 17. Also contact a qualified
service person or gas supplier for
repairs. Until repairs are made, light
pilot with match. To light pilot with
match, see Manual Lighting Proce-
dure.
OPERATING
HEATER
Continued
CAUTION: Do not try to ad-
just heating levels by using the
manual shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Slightly press in control knob and
turn clockwise to the
PILOT/IGN position.
2. Fully press in control knob and turn
clockwise to the OFF posi-
tion.
3. Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
Slightly press in control knob and turn
clockwise to the PILOT position.
1. Remove front panel (see Figure 6,
page 8).
2. Follow steps 1 through 5 under Light-
ing Instructions.
3. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
5. Replace front panel.
MANUAL LIGHTING
PROCEDURE
Figure 18 - Control Knob In The OFF
Position
Figure 19 - Pilot
8. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
9. To light burner, slightly press in con-
trol knob and turn counterclockwise
. Release downward pres-
sure on control knob while turning.
Set control knob to desired heating
position.
Note:
Both HIGH, MED, and LOW
are locked positions. You must press
in control knob before turning it
from these positions.
Thermocouple
Ignitor Electrode
Pilot Burner