Supplied By www.heating spares.co Tel. 0161 620 6677
22
4000123434-2
10316
Diagram 10.5
RESTRICTOR
FAN
10 Horizontal Telescopic Rear Flue Installation
10.2 Sealed chamber cover
• Unscrew and remove the two retaining screws from the sealed
chamber cover, see diagram 10.2
• Lift cover up and off pins on top of boiler.
10.3 Fan Removal, refer to diagram 10.3
• Disconnect power supply leads and earth lead from fan.
• Unscrew and remove the two fan retaining bolts.
• Ease the fan down and forwards to remove.
10.4 Flue Connection, refer to diagram 10.4
Pull the flue assembly into the spigot bayonet connection and
twist anti-clockwise to lock.
10.5 Restrictor, refer to diagram 10.5
For flue systems less than 0.5m long, fit the flue restrictor
supplied in document envelope into the fan outlet, see diagram
10.5.
10.6 Fan Securing, refer to diagram 10.3
Ensure fan outlet seal is in position, see diagram 10.5, then fit
the fan into the flue duct and secure to the flue collector with
screws previously removed.
Replace chamber cover and secure with screws previously
removed.
Diagram 10.2
9533
Diagram 10.4
Diagram 10.3
9741
POWER
SUPPLY
LEADS
EARTH
LEAD
FAN RETAINING
BOLTS
TWIST ANTI-CLOCKWISE
& LOCK AT 90
O
POSITION
NOTE: Please check orientation
when engaging bayonet spigot
SEAL