0020313973_01 Compact Installation and maintenance instructions 25
8. To avoid short circuits resulting from loose individual
wires, fit conductor end sleeves on the stripped ends of
the conductors.
9. Screw the respective plug to the connection cable.
10. Check whether all conductors are inserted mechanic-
ally securely in the plug terminals. Remedy this if ne-
cessary.
11. Plug the plug into the associated PCB slot.
Wiring diagram ( Page 52)
7.9.4 Establishing the power supply
1. Provide one common power supply for the boiler and
for the corresponding control:
Power supply: single-phase, 230 V, 50 Hz
Fuse: 3 A
2. Ensure that the mains voltage is 230 V.
3. Connect the product using a fixed connection and an
electrical partition with a contact gap of at least 3 mm
(e.g. fuses or power switches).
4. Make sure that access to the power supply is always
available and is not covered or blocked.
7.9.5 Connecting the control
Note
When connecting to an eBUS room thermostat
after starting up, establish the connection in or-
der to set the heating flow and domestic hot water
temperature on the product to the relevant max-
imum value.
BUS
24V
+
24V=
RT BUS
Burner
off
X106
X41
1 2 3
4
5
1 Limit thermostat for
underfloor heating
2 Control 24 V (ON/OFF)
3 eBUS control or radio
receiver unit
4 Outdoor temperature
sensor, wired
5 eBUS control or radio
receiver unit
1. Ensure that the product is voltage-free.
2. Carry out the wiring. ( Page 24)
3. Alternatives 1 Connecting the weather-
compensated control or room thermostat via
eBUS:
Connect the control to the BUS connection (3) or
(5).
Bridge the 24 VRT connection, if no bridge is
present.
3.
Alternatives 2 Connecting the low-voltage
control (24 V):
Remove the bridge and connect the control to the
24 V = RT (2) connection.
3.
Alternatives 3 Connecting a limit thermostat
for underfloor heating:
Remove the bridge and connect the limit thermostat
to the Burner off (1) connection.

Table of Contents

Other manuals for Glow-worm Compact 28c-AS/1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Compact 28c-AS/1 and is the answer not in the manual?

Glow-worm Compact 28c-AS/1 Specifications

General IconGeneral
BrandGlow-worm
ModelCompact 28c-AS/1
CategoryBoiler
LanguageEnglish

Related product manuals