0020239568_03 Ultimate 3 Installation and maintenance instructions 23
Condition: 230 V 3-wire connection
Ensure that the control is designed for a maximum nom-
inal current of 7 A.
Connect the control to the main plug X1.
Terminal assignment: L line, N neutral conductor,
earth
Draw the end user's attention to the fact that the follow-
ing features are present with this installation type.
The frost protection function is deactivated. If the
product is installed in a room where there is a risk
of frost and it has not been protected by a room ther-
mostat, install an additional frost protection thermo-
stat.
The pump programmes are not active.
If the product is switched off, the display is switched
off.
Each time the unit is started, the fan runs for
20 seconds.
Residual heat in the heating return may result in the
product blocking the burner for 10 minutes.
4. Close the electronics box.