14 Fault Finding
Diagnostic Menu
The Diagnostic Menu provides the ability to view and
change certain parameters.
See Diagram 14.8 for available parameters.
To enter the diagnostic menu:
a) Press and hold the ‘MODE’ and ‘+’ button for 5
seconds. The display will change to ‘0’.
b) Use the ‘+’ or ‘-’ buttons to scroll to 96 (This is the
installer level access password).
c) Press and hold ‘MODE’ for 5 seconds to conrm, see
diagram 14.6.
Use the ‘+’ or ‘-’ buttons to view the appropriate
diagnostic number, see diagram 14.7.
a) Press ‘MODE’ to see appropriate value.
b) Press ‘MODE’ again to return to main diagnostic
menu.
c) The values can be changed by pressing ‘+’ or ’-’
when the value is displayed.
d) Press and hold ‘MODE’ 5 seconds to conrm.
(NOTE: Only certain parameters can be adjusted)
To exit the diagnostic menu press the ‘MODE’ and ‘+’
buttons.
Diagram 14.7
INSTALLER LEVEL
DISPLAY FLASHES ALTERNATELY BETWEEN
THE INSTALLER LEVEL AND THE
DIAGNOSTIC NUMBER.
DIAGNOSTIC NUMBER
13707

Other manuals for Glow-worm Ultracom 30cx

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Ultracom 30cx and is the answer not in the manual?

Glow-worm Ultracom 30cx Specifications

General IconGeneral
BrandGlow-worm
ModelUltracom 30cx
CategoryBoiler
LanguageEnglish

Related product manuals