MALFUNCTION
08/2012 17
Display
Malfunction/Message
Troubleshooting
Sensor for start button
responds even as the
stripper is switched on.
1. Disconnect the stripper from the power
supply and carefully clean the start button
with compressed air.
2. Disconnect the stripper from the power
supply, disassemble the start button and
blow out the metal tube with compressed
air.
The sensor for the front
limit position is not
activated after the
machine was started /
there is no contact.
1. Switch off CS 60. Wait until the display
goes out and restart the CS 60.
If the error is still remains:
2. a.) Switch off CS 60
b.) Remove receptacle tray (protective
cover)
c.) Remove the clamping jaw cartridge
d.) Check if something is gotten jammed
between blade cover and clamping jaw
cartridge
e.) Check if a screw is loose at the blade
cover.
If necessary remove the jammed part /
tighten the loose screw(s).